Ortech OIF4-140 Exhaust Fan Specifications

ENERGY STAR PD #3999566 · In-line (single-port) · Qualified 2025-03-07
Verified Specification Summary

The Ortech OIF4-140 (Inline Fan 4inch) moves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 4.4 CFM/W efficacy, sizing bathrooms up to 120 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech OIF4-140 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
0.1" test only
Motor Draw
27.3 W (10.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech OIF4-140 vs. 1,145-Model ENERGY STAR Benchmarks show?

Ortech OIF4-140 (EPA filing PD #3999566) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Ortech registers 27 certified models, with SKU OIF4-140 (series: Inline Fan 4inch) (PD #3999566) certified since 2025-03-07. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 27.3 watts, about 10.0 kWh/yr (~$1.60/yr at $0.16/kWh) for 1 hr/day shower timers or 239.1 kWh/yr (~$38.26/yr) continuously. Closest competing matches include Greenheck SP-B110ES (118.0 CFM) and KORA SBF110N (119.2 CFM).

How does duct geometry alter Ortech OIF4-140 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Ortech OIF4-140?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Ortech OIF4-140 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series OIF4-140 / Inline Fan 4inch PD ID 3999566 (Qualified 2025-03-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Ortech OIF4-140 ventilate safely?

Sizing outputs below convert Ortech OIF4-140 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Ortech OIF4-140
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)10.0 kWh/yr (~$1.60/yr)27.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2239.1 kWh/yr (~$38.26/yr)27.3 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Ortech OIF4-140 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter
Broan 791LEDM 110 / 93.4 CFM 1.5 sones 4.3 CFM/W 4 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Commercial Electric BPT14-24OD-H 110 / 98.1 CFM 1.5 sones 4.3 CFM/W 4 in. diameter

Will Ortech OIF4-140 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Ortech OIF4-140 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Ortech OIF4-140 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Ortech OIF4-140.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Ortech OIF4-140?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Ortech OIF4-140.

How much airflow does Ortech OIF4-140 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Ortech OIF4-140 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Ortech OIF4-140 disturb adjacent bedrooms during night use?

Acoustic measurement places Ortech OIF4-140 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Ortech OIF4-140 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Ortech OIF4-140 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Ortech OIF4-140 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech OIF4-140's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech OIF4-140?

Ortech OIF4-140 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech OIF4-140's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech OIF4-140's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Ortech OIF4-140 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Ortech OIF4-140 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Ortech OIF4-140?

Do not force Ortech OIF4-140 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories