Fantech FR 100 (411330) Exhaust Fan Specifications

ENERGY STAR PD #4005525 · In-line (single-port) · Qualified 2025-03-21
Verified Specification Summary

In EPA dataset 8dv7-nngq, Fantech FR 100 (411330) tests at 120 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 6.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 120 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FR 100 (411330) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
6.3 CFM/W (#445/1,145)
Static Retention
0.1" test only
Motor Draw
19.0 W (6.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FR 100 (411330) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FR 100 (411330) (EPA filing PD #4005525) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 4 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Fantech's 52-unit lineup, FR 100 (411330) (series: FR Series) carries PD #4005525 dating to 2025-03-21. Lighting kit: No. At 6.3 CFM/W (#445 of 1,145, top 38.9% of 1,145 rated models, more efficient than 61.1% of rated models, 1.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 19.0 watts, about 6.9 kWh/yr (~$1.10/yr at $0.16/kWh) for 1 hr/day shower timers or 166.4 kWh/yr (~$26.62/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Tech Drive TD-BF-10 (110.0 CFM).

Why avoid unvented attic termination with Fantech FR 100 (411330)?

Under ASHRAE 62.2 best practice, Fantech FR 100 (411330) needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Fantech FR 100 (411330)?

Before cutting ceiling drywall or sizing attic transitions for Fantech FR 100 (411330), confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FR 100 (411330) / FR Series PD ID 4005525 (Qualified 2025-03-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Fantech FR 100 (411330)?

Bathroom ventilation sizing below maps Fantech FR 100 (411330) motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Fantech FR 100 (411330)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.9 kWh/yr (~$1.10/yr)19.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2166.4 kWh/yr (~$26.62/yr)19.0 W x 8,760 hrs / 1,000

What peer models sit nearest Fantech FR 100 (411330) in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech FR 100 (411330).

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Tech Drive TD-BF-10 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
Tech Drive TD-BF-10-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
VENTECHLATION BPT14-24TG-H 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter
VENTECHLATION BPT14-24TGHS 110 / 99 CFM 1.5 sones 4.8 CFM/W 4 in. diameter

What percentage of room demand does Fantech FR 100 (411330) cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech FR 100 (411330) tested delivery.

Does Fantech FR 100 (411330) suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Fantech FR 100 (411330) for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 120 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 120 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Fantech FR 100 (411330)?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech FR 100 (411330).

Does duct resistance cut Fantech FR 100 (411330) airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Fantech FR 100 (411330) achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Fantech FR 100 (411330) occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Fantech FR 100 (411330) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Fantech FR 100 (411330) add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Fantech FR 100 (411330) averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Fantech FR 100 (411330) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FR 100 (411330)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FR 100 (411330)?

Fantech FR 100 (411330) features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FR 100 (411330)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FR 100 (411330)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Does Fantech FR 100 (411330) pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Fantech FR 100 (411330) easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Fantech FR 100 (411330) in a bathroom remodel?

Avoid specifying Fantech FR 100 (411330) in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories