Certified by EPA ENERGY STAR, Air King ESQZ2303 delivers 100 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 6.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 100 sq ft (8-ft height) or 88 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESQZ2303 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 6.1 CFM/W (#448/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 16.4 W (6.0 kWh/yr)
- Duct & Tier
- 3.25 x 1 in. rectangular · Standard

What does Air King ESQZ2303 vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King ESQZ2303 (EPA filing PD #2369802) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 100 CFM (#621 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.
Air King maintains 62 active ENERGY STAR blowers; ESQZ2303 (series: Air King) (PD #2369802) gained qualification on 2020-11-20. Lighting kit: Yes. At 6.1 CFM/W (#448 of 1,145, top 40.0% of 1,145 rated models, more efficient than 60.0% of rated models, 1.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 16.4 watts, about 6.0 kWh/yr (~$0.96/yr at $0.16/kWh) for 1 hr/day shower timers or 143.7 kWh/yr (~$22.99/yr) continuously. Closest competing matches include Utilitech 7115-01 (100.0 CFM) and Delta 100LED (100.0 CFM).
Why does rigid 3.25 x 1 in. rectangular ducting protect Air King ESQZ2303 airflow?
Connecting Air King ESQZ2303 through rigid 3.25 x 1 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Air King ESQZ2303 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King ESQZ2303 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ESQZ2303 / Air King | PD ID 2369802 (Qualified 2020-11-20) |
| Duct Connection | 3.25 x 1 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (100 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Air King ESQZ2303?
Calculated coverage metrics translate Air King ESQZ2303 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 100 sq ft | 1 CFM/sq ft @ 100 CFM |
| Tall Bath (9-ft Ceiling) | Up to 88 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 50 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.0 kWh/yr (~$0.96/yr) | 16.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 143.7 kWh/yr (~$22.99/yr) | 16.4 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Air King ESQZ2303?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-01 | 100 / 95.4 CFM | 1.5 sones | 6.5 CFM/W | 4 in. diameter |
| Delta 100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Delta GBR100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Delta ITG100 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
Does Air King ESQZ2303 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King ESQZ2303 percentage capacity without sending data.
Who should not install Air King ESQZ2303 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King ESQZ2303 for residential use.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 100 CFM net static output
- Primary match: Collar pairs with 3.25 x 1 in. rectangular duct straight outdoors
Which homeowner questions come up most for Air King ESQZ2303?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King ESQZ2303.
How does Air King ESQZ2303 sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Air King ESQZ2303 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Air King ESQZ2303?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Air King ESQZ2303 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESQZ2303's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King ESQZ2303?
Air King ESQZ2303 features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King ESQZ2303's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESQZ2303's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King ESQZ2303 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King ESQZ2303 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Air King ESQZ2303 undersized or poorly matched for a bath renovation?
Skip Air King ESQZ2303 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Air King ESQZ2303 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King ESQZ2303 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3.25 x 1 in. rectangular duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)