Air King LEDAK100D Exhaust Fan Specifications

ENERGY STAR PD #2293226 · Bathroom/Utility Room · Qualified 2017-03-24
Verified Specification Summary

Rated for 100 CFM open-air (83.3 CFM at 0.25 in. w.g.), Air King LEDAK100D omits a published 0.1-inch sone rating and delivers 3.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 83 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King LEDAK100D Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 83.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
83.3% @ 0.25"
Motor Draw
26.3 W (9.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King LEDAK100D vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King LEDAK100D (EPA filing PD #2293226) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 83.3 CFM at 0.25 in. w.g. (83.3% retention, 4.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; LEDAK100D (series: Air King) (PD #2293226) gained qualification on 2017-03-24. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 26.3 watts, about 9.6 kWh/yr (~$1.54/yr at $0.16/kWh) for 1 hr/day shower timers or 230.4 kWh/yr (~$36.86/yr) continuously. Closest competing matches include Hunter 90064A (100.0 CFM) and Hunter 90065A (100.0 CFM).

How do flex elbows choke Air King LEDAK100D at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Air King LEDAK100D moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Air King LEDAK100D meet residential exhaust fan code specs?

Inspect Air King LEDAK100D mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series LEDAK100D / Air King PD ID 2293226 (Qualified 2017-03-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (83.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Air King LEDAK100D airflow output?

Annual electricity figures and room square-footage ceilings below reflect Air King LEDAK100D tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Air King LEDAK100D
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 83 sq ft1 CFM/sq ft @ 83.3 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 33 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.6 kWh/yr (~$1.54/yr)26.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2230.4 kWh/yr (~$36.86/yr)26.3 W x 8,760 hrs / 1,000

Which competing models share Air King LEDAK100D airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hunter 90064A 100 / 89.6 CFM 1.5 sones 3.9 CFM/W 4 in. diameter
Hunter 90065A 100 / 89.6 CFM 1.5 sones 3.9 CFM/W 4 in. diameter
Anzzi EF-AZ106MB 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Anzzi EF-AZ106WH 100 / 92.8 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Fantech SMPL100 (484302) 100 / 91.2 CFM 1.5 sones 4.0 CFM/W 4 in. diameter

How much airflow margin does Air King LEDAK100D give your bath?

Run a quick local room-volume check for Air King LEDAK100D by entering square footage and ceiling height to spot under-vented steam risks early.

What plumbing or duct constraints rule out Air King LEDAK100D?

Compare where Air King LEDAK100D excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 33 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 83 sq ft with 8-ft ceilings (74 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Air King LEDAK100D?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King LEDAK100D.

Is Air King LEDAK100D quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Air King LEDAK100D produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Air King LEDAK100D energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Air King LEDAK100D pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King LEDAK100D's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King LEDAK100D?

Air King LEDAK100D features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King LEDAK100D's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King LEDAK100D's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Air King LEDAK100D serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Air King LEDAK100D supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Air King LEDAK100D for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Air King LEDAK100D lacks adequate reserve.

How does Air King LEDAK100D handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Air King LEDAK100D yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.