Akicon AK18CL1-B Exhaust Fan Specifications

ENERGY STAR PD #3619588 · Bathroom/Utility Room · Qualified 2024-07-05
Verified Specification Summary

The Akicon AK18CL1-B (AK18CL1-B) moves 100 CFM at 0.1 in. w.g. (86.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.6 CFM/W efficacy, sizing bathrooms up to 86 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK18CL1-B Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 86.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
86.8% @ 0.25"
Motor Draw
10.4 W (3.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK18CL1-B vs. 1,145-Model ENERGY STAR Benchmarks show?

Akicon AK18CL1-B (EPA filing PD #3619588) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.8 CFM out of 100 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Akicon registers 14 certified models, with SKU AK18CL1-B (series: AK18CL1-B) (PD #3619588) certified since 2024-07-05. Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.4 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 91.1 kWh/yr (~$14.58/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How does duct geometry alter Akicon AK18CL1-B static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Akicon AK18CL1-B?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Akicon AK18CL1-B alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK18CL1-B / AK18CL1-B PD ID 3619588 (Qualified 2024-07-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (86.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Akicon AK18CL1-B ventilate safely?

Sizing outputs below convert Akicon AK18CL1-B tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Akicon AK18CL1-B
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 86 sq ft1 CFM/sq ft @ 86.8 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 36 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.8 kWh/yr (~$0.61/yr)10.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.291.1 kWh/yr (~$14.58/yr)10.4 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Akicon AK18CL1-B closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Will Akicon AK18CL1-B clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Akicon AK18CL1-B satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install Akicon AK18CL1-B in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Akicon AK18CL1-B for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 36 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 86 sq ft with 8-ft ceilings (77 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Akicon AK18CL1-B?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Akicon AK18CL1-B.

When is Akicon AK18CL1-B undersized or poorly matched for a bath renovation?

Skip Akicon AK18CL1-B if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Akicon AK18CL1-B CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Akicon AK18CL1-B registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Akicon AK18CL1-B sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Akicon AK18CL1-B produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Akicon AK18CL1-B?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Akicon AK18CL1-B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK18CL1-B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK18CL1-B?

Akicon AK18CL1-B features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK18CL1-B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK18CL1-B's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Akicon AK18CL1-B satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Akicon AK18CL1-B clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)