Akicon AK18CL1-S Exhaust Fan Specifications

ENERGY STAR PD #3619587 · Bathroom/Utility Room · Qualified 2024-07-05
Verified Specification Summary

In EPA dataset 8dv7-nngq, Akicon AK18CL1-S tests at 100 CFM free discharge (86.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 86 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK18CL1-S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 86.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
86.8% @ 0.25"
Motor Draw
10.4 W (3.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Akicon AK18CL1-S vs. 1,145-Model ENERGY STAR Benchmarks show?

Akicon AK18CL1-S (EPA filing PD #3619587) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.8 CFM out of 100 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Akicon maintains 14 active ENERGY STAR blowers; AK18CL1-S (series: AK18CL1-S) (PD #3619587) gained qualification on 2024-07-05. Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.4 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 91.1 kWh/yr (~$14.58/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

Why avoid unvented attic termination with Akicon AK18CL1-S?

Under ASHRAE 62.2 best practice, Akicon AK18CL1-S needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Akicon AK18CL1-S?

Before cutting ceiling drywall or sizing attic transitions for Akicon AK18CL1-S, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Akicon (14 models) ENERGY STAR Certified Partner
Model Number & Series AK18CL1-S / AK18CL1-S PD ID 3619587 (Qualified 2024-07-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (86.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Akicon AK18CL1-S?

Bathroom ventilation sizing below maps Akicon AK18CL1-S motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Akicon AK18CL1-S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 86 sq ft1 CFM/sq ft @ 86.8 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 36 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.8 kWh/yr (~$0.61/yr)10.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.291.1 kWh/yr (~$14.58/yr)10.4 W x 8,760 hrs / 1,000

What peer models sit nearest Akicon AK18CL1-S in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Akicon AK18CL1-S.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

What percentage of room demand does Akicon AK18CL1-S cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Akicon AK18CL1-S tested delivery.

Does Akicon AK18CL1-S suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Akicon AK18CL1-S for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 86.8 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 86 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Akicon AK18CL1-S?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Akicon AK18CL1-S.

Does duct resistance cut Akicon AK18CL1-S airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Akicon AK18CL1-S achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Akicon AK18CL1-S occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Akicon AK18CL1-S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Akicon AK18CL1-S add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Akicon AK18CL1-S averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Akicon AK18CL1-S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK18CL1-S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Akicon AK18CL1-S?

Akicon AK18CL1-S features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Akicon AK18CL1-S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK18CL1-S's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Akicon AK18CL1-S pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Akicon AK18CL1-S easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Akicon AK18CL1-S in a bathroom remodel?

Avoid specifying Akicon AK18CL1-S in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.