Homeowners specifying Akicon AK18CL1-W gain 100 CFM at 0.1 in. w.g. (86.8 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, venting bathrooms up to 86 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Akicon AK18CL1-W Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 86.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.6 CFM/W (#206/1,145)
- Static Retention
- 86.8% @ 0.25"
- Motor Draw
- 10.4 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Akicon AK18CL1-W vs. 1,145-Model ENERGY STAR Benchmarks show?
Akicon AK18CL1-W (EPA filing PD #3619589) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 86.8 CFM out of 100 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Akicon registers 14 certified models, with SKU AK18CL1-W (series: AK18CL1-W) (PD #3619589) certified since 2024-07-05. Lighting kit: Yes. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.4 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 91.1 kWh/yr (~$14.58/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
Which exterior damper path suits Akicon AK18CL1-W best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Akicon AK18CL1-W housings.
Where do Akicon AK18CL1-W acoustic and static metrics stand?
Compare Akicon AK18CL1-W published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Akicon (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AK18CL1-W / AK18CL1-W | PD ID 3619589 (Qualified 2024-07-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (86.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Akicon AK18CL1-W handle taller ceilings or walk-in tub steam?
Evaluate how Akicon AK18CL1-W scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 86 sq ft | 1 CFM/sq ft @ 86.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 77 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 36 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.4 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 91.1 kWh/yr (~$14.58/yr) | 10.4 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Akicon AK18CL1-W?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Is Akicon AK18CL1-W sized right for your shower or tub room?
Check whether Akicon AK18CL1-W clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Where should contractors skip Akicon AK18CL1-W on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Akicon AK18CL1-W carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 36 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 86.8 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Akicon AK18CL1-W?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Akicon AK18CL1-W.
Will long attic ducting choke Akicon AK18CL1-W capacity?
Because static drag at 0.25 in. w.g. lowers Akicon AK18CL1-W from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Akicon AK18CL1-W compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Akicon AK18CL1-W produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Akicon AK18CL1-W consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Akicon AK18CL1-W draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Akicon AK18CL1-W pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Akicon AK18CL1-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Akicon AK18CL1-W?
Akicon AK18CL1-W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Akicon AK18CL1-W's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Akicon AK18CL1-W's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Akicon AK18CL1-W score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Akicon AK18CL1-W delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Akicon AK18CL1-W?
Rule out Akicon AK18CL1-W when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)