Skip to main content
Grant Estimator

AUPU BF4-S10C Exhaust Fan Specifications

ENERGY STAR PD #4638614 · Bathroom/Utility Room · Qualified 2026-06-10
Verified Specification Summary

Certified by EPA ENERGY STAR, AUPU BF4-S10C delivers 100 CFM free-air (107.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 107 sq ft (8-ft height) or 95 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF4-S10C Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 107.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.9 CFM/W (#189/1,145)
Static Retention
107.8% @ 0.25"
Motor Draw
10.1 W (3.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU BF4-S10C vs. 1,145-Model ENERGY STAR Benchmarks show?

AUPU BF4-S10C (EPA filing PD #4638614) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.8 CFM out of 100 CFM (107.8% retention, 20.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BF4-S10C (series: BF4) (PD #4638614) among 35 AUPU entries qualified through 2026-06-10. Lighting kit: No. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.1 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 88.5 kWh/yr (~$14.16/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect AUPU BF4-S10C airflow?

Connecting AUPU BF4-S10C through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify AUPU BF4-S10C performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU BF4-S10C lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series BF4-S10C / BF4 PD ID 4638614 (Qualified 2026-06-10)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (107.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit AUPU BF4-S10C?

Calculated coverage metrics translate AUPU BF4-S10C airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AUPU BF4-S10C
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 107 sq ft1 CFM/sq ft @ 107.8 CFM
Tall Bath (9-ft Ceiling)Up to 95 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 57 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.7 kWh/yr (~$0.59/yr)10.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.288.5 kWh/yr (~$14.16/yr)10.1 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to AUPU BF4-S10C?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does AUPU BF4-S10C match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU BF4-S10C percentage capacity without sending data.

Does AUPU BF4-S10C suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU BF4-S10C for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 57 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 107.8 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for AUPU BF4-S10C?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU BF4-S10C.

Who should NOT install AUPU BF4-S10C in a bathroom remodel?

Avoid specifying AUPU BF4-S10C in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut AUPU BF4-S10C airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU BF4-S10C achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does AUPU BF4-S10C occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., AUPU BF4-S10C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does AUPU BF4-S10C add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, AUPU BF4-S10C averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can AUPU BF4-S10C pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF4-S10C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU BF4-S10C?

AUPU BF4-S10C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU BF4-S10C's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF4-S10C's safe coverage footprint from 50 sq ft to 44 sq ft.

Does AUPU BF4-S10C pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU BF4-S10C easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories