Certified by EPA ENERGY STAR, AUPU BF4-S10C delivers 100 CFM free-air (107.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 107 sq ft (8-ft height) or 95 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF4-S10C Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 107.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.9 CFM/W (#189/1,145)
- Static Retention
- 107.8% @ 0.25"
- Motor Draw
- 10.1 W (3.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU BF4-S10C vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU BF4-S10C (EPA filing PD #4638614) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.8 CFM out of 100 CFM (107.8% retention, 20.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BF4-S10C (series: BF4) (PD #4638614) among 35 AUPU entries qualified through 2026-06-10. Lighting kit: No. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.1 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 88.5 kWh/yr (~$14.16/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect AUPU BF4-S10C airflow?
Connecting AUPU BF4-S10C through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify AUPU BF4-S10C performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU BF4-S10C lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF4-S10C / BF4 | PD ID 4638614 (Qualified 2026-06-10) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (107.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit AUPU BF4-S10C?
Calculated coverage metrics translate AUPU BF4-S10C airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 107 sq ft | 1 CFM/sq ft @ 107.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 57 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.7 kWh/yr (~$0.59/yr) | 10.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 88.5 kWh/yr (~$14.16/yr) | 10.1 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to AUPU BF4-S10C?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Does AUPU BF4-S10C match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU BF4-S10C percentage capacity without sending data.
Does AUPU BF4-S10C suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU BF4-S10C for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 57 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 107.8 CFM net static output
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for AUPU BF4-S10C?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU BF4-S10C.
Who should NOT install AUPU BF4-S10C in a bathroom remodel?
Avoid specifying AUPU BF4-S10C in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut AUPU BF4-S10C airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU BF4-S10C achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does AUPU BF4-S10C occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., AUPU BF4-S10C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does AUPU BF4-S10C add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, AUPU BF4-S10C averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can AUPU BF4-S10C pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF4-S10C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU BF4-S10C?
AUPU BF4-S10C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU BF4-S10C's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF4-S10C's safe coverage footprint from 50 sq ft to 44 sq ft.
Does AUPU BF4-S10C pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU BF4-S10C easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)