The AUPU V4-10 (BF4-S10C) moves 100 CFM at 0.1 in. w.g. (107.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.9 CFM/W efficacy, sizing bathrooms up to 107 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU V4-10 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 107.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.9 CFM/W (#189/1,145)
- Static Retention
- 107.8% @ 0.25"
- Motor Draw
- 10.1 W (3.7 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU V4-10 vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU V4-10 (EPA filing PD #4708501) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.8 CFM out of 100 CFM (107.8% retention, 20.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: AUPU registers 35 certified models, with SKU V4-10 (series: BF4-S10C) (PD #4708501) certified since 2026-09-23. Lighting kit: No. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.1 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 88.5 kWh/yr (~$14.16/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
How does duct geometry alter AUPU V4-10 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to AUPU V4-10?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for AUPU V4-10 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | V4-10 / BF4-S10C | PD ID 4708501 (Qualified 2026-09-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (107.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can AUPU V4-10 ventilate safely?
Sizing outputs below convert AUPU V4-10 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 107 sq ft | 1 CFM/sq ft @ 107.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 95 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 57 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.7 kWh/yr (~$0.59/yr) | 10.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 88.5 kWh/yr (~$14.16/yr) | 10.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match AUPU V4-10 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will AUPU V4-10 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether AUPU V4-10 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does AUPU V4-10 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering AUPU V4-10.
Limitations & Who Should Skip
- Steam or walk-in tub room > 57 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 107 sq ft with 8-ft ceilings (95 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern AUPU V4-10?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting AUPU V4-10.
Which bathroom layouts should pick a larger blower than AUPU V4-10?
Do not force AUPU V4-10 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does AUPU V4-10 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, AUPU V4-10 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will AUPU V4-10 disturb adjacent bedrooms during night use?
Acoustic measurement places AUPU V4-10 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running AUPU V4-10 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of AUPU V4-10 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can AUPU V4-10 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU V4-10's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU V4-10?
AUPU V4-10 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU V4-10's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU V4-10's safe coverage footprint from 50 sq ft to 44 sq ft.
Is AUPU V4-10 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), AUPU V4-10 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)