Skip to main content
Grant Estimator

AUPU V4-10HF Exhaust Fan Specifications

ENERGY STAR PD #4727694 · Bathroom/Utility Room · Qualified 2026-11-04
Verified Specification Summary

Tested under HVI protocols, the AUPU V4-10HF exhaust unit achieves 100 CFM at 0.1 in. w.g. (107.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.9 CFM/W efficacy, covering standard baths up to 107 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU V4-10HF Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 107.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.9 CFM/W (#189/1,145)
Static Retention
107.8% @ 0.25"
Motor Draw
10.1 W (3.7 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU V4-10HF vs. 1,145-Model ENERGY STAR Benchmarks show?

AUPU V4-10HF (EPA filing PD #4727694) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 107.8 CFM out of 100 CFM (107.8% retention, 20.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: AUPU registers 35 certified models, with SKU V4-10HF (series: Flush) (PD #4727694) certified since 2026-11-04. Lighting kit: No. At 9.9 CFM/W (#189 of 1,145, top 17.3% of 1,145 rated models, more efficient than 82.7% of rated models, 5.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.1 watts, about 3.7 kWh/yr (~$0.59/yr at $0.16/kWh) for 1 hr/day shower timers or 88.5 kWh/yr (~$14.16/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

What attic duct routing preserves AUPU V4-10HF CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU V4-10HF, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does AUPU V4-10HF measure up on airflow and noise ratings?

Each row below breaks down AUPU V4-10HF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series V4-10HF / Flush PD ID 4727694 (Qualified 2026-11-04)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (107.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect AUPU V4-10HF CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AUPU V4-10HF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 107 sq ft1 CFM/sq ft @ 107.8 CFM
Tall Bath (9-ft Ceiling)Up to 95 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 57 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.7 kWh/yr (~$0.59/yr)10.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.288.5 kWh/yr (~$14.16/yr)10.1 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against AUPU V4-10HF?

Compare AUPU V4-10HF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size AUPU V4-10HF for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU V4-10HF verified capacity.

Where should contractors skip AUPU V4-10HF on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for AUPU V4-10HF carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 107.8 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 107 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to AUPU V4-10HF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU V4-10HF.

How much power does AUPU V4-10HF consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, AUPU V4-10HF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can AUPU V4-10HF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU V4-10HF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU V4-10HF?

AUPU V4-10HF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU V4-10HF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU V4-10HF's safe coverage footprint from 50 sq ft to 44 sq ft.

How does AUPU V4-10HF score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), AUPU V4-10HF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify AUPU V4-10HF?

Rule out AUPU V4-10HF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke AUPU V4-10HF capacity?

Because static drag at 0.25 in. w.g. lowers AUPU V4-10HF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is AUPU V4-10HF compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, AUPU V4-10HF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories