The AUPU V4-10HL1 (BF4-S10CL) moves 100 CFM at 0.1 in. w.g. (109.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.5 CFM/W efficacy, sizing bathrooms up to 109 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU V4-10HL1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 109.8 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.5 CFM/W (#234/1,145)
- Static Retention
- 109.8% @ 0.25"
- Motor Draw
- 10.5 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU V4-10HL1 vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU V4-10HL1 (EPA filing PD #4708515) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 109.8 CFM out of 100 CFM (109.8% retention, 22.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places V4-10HL1 (series: BF4-S10CL) (PD #4708515) among 35 AUPU entries qualified through 2026-09-23. Lighting kit: Yes. At 9.5 CFM/W (#234 of 1,145, top 22.1% of 1,145 rated models, more efficient than 77.9% of rated models, 4.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
How does duct geometry alter AUPU V4-10HL1 static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to AUPU V4-10HL1?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for AUPU V4-10HL1 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | V4-10HL1 / BF4-S10CL | PD ID 4708515 (Qualified 2026-09-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (109.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can AUPU V4-10HL1 ventilate safely?
Sizing outputs below convert AUPU V4-10HL1 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 109 sq ft | 1 CFM/sq ft @ 109.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 97 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 59 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match AUPU V4-10HL1 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will AUPU V4-10HL1 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether AUPU V4-10HL1 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does AUPU V4-10HL1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying AUPU V4-10HL1 for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 59 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 109 sq ft with 8-ft ceilings (97 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern AUPU V4-10HL1?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting AUPU V4-10HL1.
What acoustic sone tier does AUPU V4-10HL1 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., AUPU V4-10HL1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does AUPU V4-10HL1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, AUPU V4-10HL1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can AUPU V4-10HL1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU V4-10HL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU V4-10HL1?
AUPU V4-10HL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU V4-10HL1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU V4-10HL1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does AUPU V4-10HL1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), AUPU V4-10HL1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install AUPU V4-10HL1 in a bathroom remodel?
Avoid specifying AUPU V4-10HL1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut AUPU V4-10HL1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, AUPU V4-10HL1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.