Rated for 110 CFM open-air (93.9 CFM at 0.25 in. w.g.), AUPU AV0511DSL3 omits a published 0.1-inch sone rating and delivers 7.4 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 93 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AV0511DSL3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 93.9 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.4 CFM/W (#392/1,145)
- Static Retention
- 85.4% @ 0.25"
- Motor Draw
- 14.9 W (5.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU AV0511DSL3 vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU AV0511DSL3 (EPA filing PD #2333326) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.9 CFM out of 110 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: AUPU registers 35 certified models, with SKU AV0511DSL3 (series: AV) (PD #2333326) certified since 2019-02-08. Lighting kit: Yes. At 7.4 CFM/W (#392 of 1,145, top 34.8% of 1,145 rated models, more efficient than 65.2% of rated models, 2.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.9 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 130.5 kWh/yr (~$20.88/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-N110LHA (110.0 CFM) and Delta 100LED (100.0 CFM).
How do flex elbows choke AUPU AV0511DSL3 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps AUPU AV0511DSL3 moving full rated CFM.
Does AUPU AV0511DSL3 meet residential exhaust fan code specs?
Inspect AUPU AV0511DSL3 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AV0511DSL3 / AV | PD ID 2333326 (Qualified 2019-02-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (93.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match AUPU AV0511DSL3 airflow output?
Annual electricity figures and room square-footage ceilings below reflect AUPU AV0511DSL3 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 93 sq ft | 1 CFM/sq ft @ 93.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 83 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 43 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.4 kWh/yr (~$0.86/yr) | 14.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 130.5 kWh/yr (~$20.88/yr) | 14.9 W x 8,760 hrs / 1,000 |
Which competing models share AUPU AV0511DSL3 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Delta 100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Delta GBR100LED | 100 / 75 CFM | 1.5 sones | 7.4 CFM/W | 4 in. diameter |
| Delta ITG100 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
| Utilitech 7131-04 | 100 / 88 CFM | 1.5 sones | 7.6 CFM/W | 4 in. diameter |
How much airflow margin does AUPU AV0511DSL3 give your bath?
Run a quick local room-volume check for AUPU AV0511DSL3 by entering square footage and ceiling height to spot under-vented steam risks early.
When does AUPU AV0511DSL3 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering AUPU AV0511DSL3.
Limitations & Who Should Skip
- Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 93 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about AUPU AV0511DSL3?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to AUPU AV0511DSL3.
Will AUPU AV0511DSL3 disturb adjacent bedrooms during night use?
Acoustic measurement places AUPU AV0511DSL3 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running AUPU AV0511DSL3 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of AUPU AV0511DSL3 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can AUPU AV0511DSL3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AV0511DSL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU AV0511DSL3?
AUPU AV0511DSL3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU AV0511DSL3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AV0511DSL3's safe coverage footprint from 50 sq ft to 44 sq ft.
Is AUPU AV0511DSL3 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), AUPU AV0511DSL3 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than AUPU AV0511DSL3?
Do not force AUPU AV0511DSL3 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does AUPU AV0511DSL3 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, AUPU AV0511DSL3 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)