Tested under HVI protocols, the AUPU AVS0511DL3 exhaust unit achieves 110 CFM at 0.1 in. w.g. (111.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 7.8 CFM/W efficacy, covering standard baths up to 111 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU AVS0511DL3 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 111.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.8 CFM/W (#365/1,145)
- Static Retention
- 101.1% @ 0.25"
- Motor Draw
- 14.1 W (5.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU AVS0511DL3 vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU AVS0511DL3 (EPA filing PD #2333768) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 111.2 CFM out of 110 CFM (101.1% retention, 13.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2333768 verifies AVS0511DL3 (series: AVS) under AUPU (35 listed models, qualified 2019-02-08). Lighting kit: Yes. At 7.8 CFM/W (#365 of 1,145, top 32.8% of 1,145 rated models, more efficient than 67.2% of rated models, 3.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 14.1 watts, about 5.1 kWh/yr (~$0.82/yr at $0.16/kWh) for 1 hr/day shower timers or 123.5 kWh/yr (~$19.76/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).
What attic duct routing preserves AUPU AVS0511DL3 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU AVS0511DL3, preventing premature peeling paint and mold growth.
How does AUPU AVS0511DL3 measure up on airflow and noise ratings?
Each row below breaks down AUPU AVS0511DL3 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AVS0511DL3 / AVS | PD ID 2333768 (Qualified 2019-02-08) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (111.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect AUPU AVS0511DL3 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 111 sq ft | 1 CFM/sq ft @ 111.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 98 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 61 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.1 kWh/yr (~$0.82/yr) | 14.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 123.5 kWh/yr (~$19.76/yr) | 14.1 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against AUPU AVS0511DL3?
Compare AUPU AVS0511DL3 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Can you size AUPU AVS0511DL3 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU AVS0511DL3 verified capacity.
What plumbing or duct constraints rule out AUPU AVS0511DL3?
Compare where AUPU AVS0511DL3 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 111.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 111 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to AUPU AVS0511DL3?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU AVS0511DL3.
How does AUPU AVS0511DL3 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., AUPU AVS0511DL3 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is AUPU AVS0511DL3 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, AUPU AVS0511DL3 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is AUPU AVS0511DL3 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can AUPU AVS0511DL3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU AVS0511DL3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU AVS0511DL3?
AUPU AVS0511DL3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU AVS0511DL3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU AVS0511DL3's safe coverage footprint from 50 sq ft to 44 sq ft.
Can AUPU AVS0511DL3 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: AUPU AVS0511DL3 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap AUPU AVS0511DL3 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, AUPU AVS0511DL3 lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)