AUPU B6-11HL1 Exhaust Fan Specifications

ENERGY STAR PD #4708519 · Bathroom/Utility Room · Qualified 2026-09-23
Verified Specification Summary

Certified by EPA ENERGY STAR, AUPU B6-11HL1 delivers 110 CFM free-air (87.2 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 87 sq ft (8-ft height) or 77 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-11HL1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 87.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.7 CFM/W (#201/1,145)
Static Retention
79.3% @ 0.25"
Motor Draw
11.3 W (4.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU B6-11HL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

AUPU B6-11HL1 (EPA filing PD #4708519) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.2 CFM at 0.25 in. w.g. (79.3% retention, 8.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places B6-11HL1 (series: BF6-S13CL) (PD #4708519) among 35 AUPU entries qualified through 2026-09-23. Lighting kit: Yes. At 9.7 CFM/W (#201 of 1,145, top 17.9% of 1,145 rated models, more efficient than 82.1% of rated models, 5.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.3 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 99.0 kWh/yr (~$15.84/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Why does rigid 4 in. diameter ducting protect AUPU B6-11HL1 airflow?

Connecting AUPU B6-11HL1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify AUPU B6-11HL1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for AUPU B6-11HL1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series B6-11HL1 / BF6-S13CL PD ID 4708519 (Qualified 2026-09-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (87.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit AUPU B6-11HL1?

Calculated coverage metrics translate AUPU B6-11HL1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for AUPU B6-11HL1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 87 sq ft1 CFM/sq ft @ 87.2 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 37 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.1 kWh/yr (~$0.66/yr)11.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.299.0 kWh/yr (~$15.84/yr)11.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to AUPU B6-11HL1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does AUPU B6-11HL1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check AUPU B6-11HL1 percentage capacity without sending data.

Where should contractors skip AUPU B6-11HL1 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for AUPU B6-11HL1 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 37 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 87.2 CFM net static output
  • Works well for: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for AUPU B6-11HL1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around AUPU B6-11HL1.

How does AUPU B6-11HL1 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-11HL1 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify AUPU B6-11HL1?

Rule out AUPU B6-11HL1 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke AUPU B6-11HL1 capacity?

Because static drag at 0.25 in. w.g. lowers AUPU B6-11HL1 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is AUPU B6-11HL1 compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, AUPU B6-11HL1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does AUPU B6-11HL1 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, AUPU B6-11HL1 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can AUPU B6-11HL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-11HL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU B6-11HL1?

AUPU B6-11HL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU B6-11HL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-11HL1's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)