Tested under HVI protocols, the AUPU BF6-S13C exhaust unit achieves 110 CFM at 0.1 in. w.g. (89.5 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.7 CFM/W efficacy, covering standard baths up to 89 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF6-S13C Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 89.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.7 CFM/W (#201/1,145)
- Static Retention
- 81.4% @ 0.25"
- Motor Draw
- 11.3 W (4.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU BF6-S13C vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU BF6-S13C (EPA filing PD #4573318) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 89.5 CFM at 0.25 in. w.g. (81.4% retention, 6.3 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places BF6-S13C (series: BF6-S13C) (PD #4573318) among 35 AUPU entries qualified through 2026-03-11. Lighting kit: No. At 9.7 CFM/W (#201 of 1,145, top 17.9% of 1,145 rated models, more efficient than 82.1% of rated models, 5.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.3 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 99.0 kWh/yr (~$15.84/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
What attic duct routing preserves AUPU BF6-S13C CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU BF6-S13C, preventing premature peeling paint and mold growth.
How does AUPU BF6-S13C measure up on airflow and noise ratings?
Each row below breaks down AUPU BF6-S13C certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF6-S13C / BF6-S13C | PD ID 4573318 (Qualified 2026-03-11) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (89.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect AUPU BF6-S13C CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 89 sq ft | 1 CFM/sq ft @ 89.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 79 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 39 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.0 kWh/yr (~$15.84/yr) | 11.3 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against AUPU BF6-S13C?
Compare AUPU BF6-S13C side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Can you size AUPU BF6-S13C for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU BF6-S13C verified capacity.
Where should contractors skip AUPU BF6-S13C on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for AUPU BF6-S13C carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 89.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 89 sq ft
- Works well for: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to AUPU BF6-S13C?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU BF6-S13C.
How loud is AUPU BF6-S13C compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, AUPU BF6-S13C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does AUPU BF6-S13C consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, AUPU BF6-S13C draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can AUPU BF6-S13C pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF6-S13C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU BF6-S13C?
AUPU BF6-S13C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU BF6-S13C's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF6-S13C's safe coverage footprint from 50 sq ft to 44 sq ft.
How does AUPU BF6-S13C score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), AUPU BF6-S13C delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify AUPU BF6-S13C?
Rule out AUPU BF6-S13C when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke AUPU BF6-S13C capacity?
Because static drag at 0.25 in. w.g. lowers AUPU BF6-S13C from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)