The AUPU BF6-S13CL (BF6-S13CL) moves 110 CFM at 0.1 in. w.g. (87.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.7 CFM/W efficacy, sizing bathrooms up to 87 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU BF6-S13CL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 87.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.7 CFM/W (#201/1,145)
- Static Retention
- 79.3% @ 0.25"
- Motor Draw
- 11.3 W (4.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AUPU BF6-S13CL vs. 1,145-Model ENERGY STAR Benchmarks show?
AUPU BF6-S13CL (EPA filing PD #4573320) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.2 CFM at 0.25 in. w.g. (79.3% retention, 8.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside AUPU's 35-unit lineup, BF6-S13CL (series: BF6-S13CL) carries PD #4573320 dating to 2026-03-11. Lighting kit: Yes. At 9.7 CFM/W (#201 of 1,145, top 17.9% of 1,145 rated models, more efficient than 82.1% of rated models, 5.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.3 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 99.0 kWh/yr (~$15.84/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How does duct geometry alter AUPU BF6-S13CL static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to AUPU BF6-S13CL?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for AUPU BF6-S13CL alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AUPU (35 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BF6-S13CL / BF6-S13CL | PD ID 4573320 (Qualified 2026-03-11) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (87.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can AUPU BF6-S13CL ventilate safely?
Sizing outputs below convert AUPU BF6-S13CL tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 87 sq ft | 1 CFM/sq ft @ 87.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 77 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 37 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.1 kWh/yr (~$0.66/yr) | 11.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 99.0 kWh/yr (~$15.84/yr) | 11.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match AUPU BF6-S13CL closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will AUPU BF6-S13CL clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether AUPU BF6-S13CL satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does AUPU BF6-S13CL fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering AUPU BF6-S13CL.
Limitations & Who Should Skip
- Steam or walk-in tub room > 37 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 87 sq ft with 8-ft ceilings (77 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern AUPU BF6-S13CL?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting AUPU BF6-S13CL.
How much airflow does AUPU BF6-S13CL retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, AUPU BF6-S13CL produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will AUPU BF6-S13CL disturb adjacent bedrooms during night use?
Acoustic measurement places AUPU BF6-S13CL at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running AUPU BF6-S13CL continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of AUPU BF6-S13CL draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can AUPU BF6-S13CL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU BF6-S13CL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AUPU BF6-S13CL?
AUPU BF6-S13CL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AUPU BF6-S13CL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU BF6-S13CL's safe coverage footprint from 50 sq ft to 44 sq ft.
Is AUPU BF6-S13CL code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), AUPU BF6-S13CL clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than AUPU BF6-S13CL?
Do not force AUPU BF6-S13CL into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)