Skip to main content
Grant Estimator

Broan AE50110DC = A000HFKT with AE50110DCF Exhaust Fan Specifications

ENERGY STAR PD #4698054 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Tested under HVI protocols, the Broan AE50110DC = A000HFKT with AE50110DCF exhaust unit achieves 110 CFM at 0.1 in. w.g. (112.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, covering standard baths up to 112 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50110DC = A000HFKT with AE50110DCF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 112.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
101.9% @ 0.25"
Motor Draw
11.5 W (4.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE50110DC = A000HFKT with AE50110DCF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AE50110DC = A000HFKT with AE50110DCF (EPA filing PD #4698054) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.1 CFM out of 110 CFM (101.9% retention, 14.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE50110DC = A000HFKT with AE50110DCF (series: INVENT) under PD #4698054 (207 models registered, 2026-09-02). Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

What attic duct routing preserves Broan AE50110DC = A000HFKT with AE50110DCF CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE50110DC = A000HFKT with AE50110DCF, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan AE50110DC = A000HFKT with AE50110DCF measure up on airflow and noise ratings?

Each row below breaks down Broan AE50110DC = A000HFKT with AE50110DCF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE50110DC = A000HFKT with AE50110DCF / INVENT PD ID 4698054 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan AE50110DC = A000HFKT with AE50110DCF CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AE50110DC = A000HFKT with AE50110DCF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.1 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2100.7 kWh/yr (~$16.11/yr)11.5 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan AE50110DC = A000HFKT with AE50110DCF?

Compare Broan AE50110DC = A000HFKT with AE50110DCF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size Broan AE50110DC = A000HFKT with AE50110DCF for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE50110DC = A000HFKT with AE50110DCF verified capacity.

When does Broan AE50110DC = A000HFKT with AE50110DCF fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE50110DC = A000HFKT with AE50110DCF.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 112.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 112 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan AE50110DC = A000HFKT with AE50110DCF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE50110DC = A000HFKT with AE50110DCF.

Will Broan AE50110DC = A000HFKT with AE50110DCF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan AE50110DC = A000HFKT with AE50110DCF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Broan AE50110DC = A000HFKT with AE50110DCF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan AE50110DC = A000HFKT with AE50110DCF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan AE50110DC = A000HFKT with AE50110DCF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50110DC = A000HFKT with AE50110DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE50110DC = A000HFKT with AE50110DCF?

Broan AE50110DC = A000HFKT with AE50110DCF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE50110DC = A000HFKT with AE50110DCF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50110DC = A000HFKT with AE50110DCF's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan AE50110DC = A000HFKT with AE50110DCF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE50110DC = A000HFKT with AE50110DCF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan AE50110DC = A000HFKT with AE50110DCF?

Do not force Broan AE50110DC = A000HFKT with AE50110DCF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan AE50110DC = A000HFKT with AE50110DCF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan AE50110DC = A000HFKT with AE50110DCF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories