Skip to main content
Grant Estimator

Broan AE50110DC = A000HFNF with AE50110DCF Exhaust Fan Specifications

ENERGY STAR PD #4698034 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Homeowners specifying Broan AE50110DC = A000HFNF with AE50110DCF gain 110 CFM at 0.1 in. w.g. (112.1 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy, venting bathrooms up to 112 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50110DC = A000HFNF with AE50110DCF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 112.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
101.9% @ 0.25"
Motor Draw
11.5 W (4.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE50110DC = A000HFNF with AE50110DCF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AE50110DC = A000HFNF with AE50110DCF (EPA filing PD #4698034) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.1 CFM out of 110 CFM (101.9% retention, 14.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places AE50110DC = A000HFNF with AE50110DCF (series: INVENT) (PD #4698034) among 207 Broan entries qualified through 2026-09-02. Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

Which exterior damper path suits Broan AE50110DC = A000HFNF with AE50110DCF best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan AE50110DC = A000HFNF with AE50110DCF housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan AE50110DC = A000HFNF with AE50110DCF acoustic and static metrics stand?

Compare Broan AE50110DC = A000HFNF with AE50110DCF published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE50110DC = A000HFNF with AE50110DCF / INVENT PD ID 4698034 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan AE50110DC = A000HFNF with AE50110DCF handle taller ceilings or walk-in tub steam?

Evaluate how Broan AE50110DC = A000HFNF with AE50110DCF scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AE50110DC = A000HFNF with AE50110DCF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.1 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2100.7 kWh/yr (~$16.11/yr)11.5 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan AE50110DC = A000HFNF with AE50110DCF?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Is Broan AE50110DC = A000HFNF with AE50110DCF sized right for your shower or tub room?

Check whether Broan AE50110DC = A000HFNF with AE50110DCF clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Who should not install Broan AE50110DC = A000HFNF with AE50110DCF in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan AE50110DC = A000HFNF with AE50110DCF for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 112.1 CFM net static output
  • Primary match: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan AE50110DC = A000HFNF with AE50110DCF?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE50110DC = A000HFNF with AE50110DCF.

When is Broan AE50110DC = A000HFNF with AE50110DCF undersized or poorly matched for a bath renovation?

Skip Broan AE50110DC = A000HFNF with AE50110DCF if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan AE50110DC = A000HFNF with AE50110DCF CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan AE50110DC = A000HFNF with AE50110DCF registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Broan AE50110DC = A000HFNF with AE50110DCF sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan AE50110DC = A000HFNF with AE50110DCF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan AE50110DC = A000HFNF with AE50110DCF?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan AE50110DC = A000HFNF with AE50110DCF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50110DC = A000HFNF with AE50110DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE50110DC = A000HFNF with AE50110DCF?

Broan AE50110DC = A000HFNF with AE50110DCF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE50110DC = A000HFNF with AE50110DCF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50110DC = A000HFNF with AE50110DCF's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan AE50110DC = A000HFNF with AE50110DCF satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan AE50110DC = A000HFNF with AE50110DCF clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories