Broan AE50110DC = A000HFKTC WITH AE50110DCF Exhaust Fan Specifications

ENERGY STAR PD #4191422 · Bathroom/Utility Room · Qualified 2025-05-23
Verified Specification Summary

The Broan AE50110DC = A000HFKTC WITH AE50110DCF (FLEX SERIES) moves 110 CFM at 0.1 in. w.g. (112.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.6 CFM/W efficacy, sizing bathrooms up to 112 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE50110DC = A000HFKTC WITH AE50110DCF Exhaust before installation.

Airflow @ 0.1" / 0.25"
110 / 112.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
101.9% @ 0.25"
Motor Draw
11.5 W (4.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE50110DC = A000HFKTC WITH AE50110DCF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan AE50110DC = A000HFKTC WITH AE50110DCF (EPA filing PD #4191422) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.1 CFM out of 110 CFM (101.9% retention, 14.2 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE50110DC = A000HFKTC WITH AE50110DCF (series: FLEX SERIES) under PD #4191422 (207 models registered, 2025-05-23). Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.5 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 100.7 kWh/yr (~$16.11/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

How does duct geometry alter Broan AE50110DC = A000HFKTC WITH AE50110DCF static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE50110DC = A000HFKTC WITH AE50110DCF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE50110DC = A000HFKTC WITH AE50110DCF / FLEX SERIES PD ID 4191422 (Qualified 2025-05-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Broan AE50110DC = A000HFKTC WITH AE50110DCF ventilate safely?

Sizing outputs below convert Broan AE50110DC = A000HFKTC WITH AE50110DCF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AE50110DC = A000HFKTC WITH AE50110DCF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.1 CFM
Tall Bath (9-ft Ceiling)Up to 99 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2100.7 kWh/yr (~$16.11/yr)11.5 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan AE50110DC = A000HFKTC WITH AE50110DCF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Will Broan AE50110DC = A000HFKTC WITH AE50110DCF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AE50110DC = A000HFKTC WITH AE50110DCF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Broan AE50110DC = A000HFKTC WITH AE50110DC fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE50110DC = A000HFKTC WITH AE50110DC.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 112 sq ft with 8-ft ceilings (99 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE50110DC = A000HFKTC WITH AE50110DCF.

Will Broan AE50110DC = A000HFKTC WITH AE50110DCF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan AE50110DC = A000HFKTC WITH AE50110DCF at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Broan AE50110DC = A000HFKTC WITH AE50110DCF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan AE50110DC = A000HFKTC WITH AE50110DCF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan AE50110DC = A000HFKTC WITH AE50110DCF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE50110DC = A000HFKTC WITH AE50110DCF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Broan AE50110DC = A000HFKTC WITH AE50110DCF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE50110DC = A000HFKTC WITH AE50110DCF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE50110DC = A000HFKTC WITH AE50110DCF's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan AE50110DC = A000HFKTC WITH AE50110DCF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE50110DC = A000HFKTC WITH AE50110DCF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan AE50110DC = A000HFKTC WITH AE50110DCF?

Do not force Broan AE50110DC = A000HFKTC WITH AE50110DCF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan AE50110DC = A000HFKTC WITH AE50110DCF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan AE50110DC = A000HFKTC WITH AE50110DCF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories