AUPU B6-11HR Exhaust Fan Specifications

ENERGY STAR PD #4708518 · Bathroom/Utility Room · Qualified 2026-09-23
Verified Specification Summary

Tested under HVI protocols, the AUPU B6-11HR exhaust unit achieves 110 CFM at 0.1 in. w.g. (87.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 9.7 CFM/W efficacy, covering standard baths up to 87 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AUPU B6-11HR Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 87.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.7 CFM/W (#201/1,145)
Static Retention
79.3% @ 0.25"
Motor Draw
11.3 W (4.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AUPU B6-11HR vs. 1,145-Model ENERGY STAR Benchmarks show?

AUPU B6-11HR (EPA filing PD #4708518) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 87.2 CFM at 0.25 in. w.g. (79.3% retention, 8.4 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms AUPU B6-11HR (series: BF6-S13CL) under PD #4708518 (35 models registered, 2026-09-23). Lighting kit: Yes. At 9.7 CFM/W (#201 of 1,145, top 17.9% of 1,145 rated models, more efficient than 82.1% of rated models, 5.0 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.3 watts, about 4.1 kWh/yr (~$0.66/yr at $0.16/kWh) for 1 hr/day shower timers or 99.0 kWh/yr (~$15.84/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

What attic duct routing preserves AUPU B6-11HR CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AUPU B6-11HR, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does AUPU B6-11HR measure up on airflow and noise ratings?

Each row below breaks down AUPU B6-11HR certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AUPU (35 models) ENERGY STAR Certified Partner
Model Number & Series B6-11HR / BF6-S13CL PD ID 4708518 (Qualified 2026-09-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (87.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect AUPU B6-11HR CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AUPU B6-11HR
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 87 sq ft1 CFM/sq ft @ 87.2 CFM
Tall Bath (9-ft Ceiling)Up to 77 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 37 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.1 kWh/yr (~$0.66/yr)11.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.299.0 kWh/yr (~$15.84/yr)11.3 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against AUPU B6-11HR?

Compare AUPU B6-11HR side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size AUPU B6-11HR for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AUPU B6-11HR verified capacity.

Where should contractors skip AUPU B6-11HR on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for AUPU B6-11HR carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 87.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 87 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to AUPU B6-11HR?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AUPU B6-11HR.

How much power does AUPU B6-11HR consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, AUPU B6-11HR draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can AUPU B6-11HR pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AUPU B6-11HR's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AUPU B6-11HR?

AUPU B6-11HR features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AUPU B6-11HR's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AUPU B6-11HR's safe coverage footprint from 50 sq ft to 44 sq ft.

How does AUPU B6-11HR score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), AUPU B6-11HR delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify AUPU B6-11HR?

Rule out AUPU B6-11HR when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke AUPU B6-11HR capacity?

Because static drag at 0.25 in. w.g. lowers AUPU B6-11HR from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is AUPU B6-11HR compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, AUPU B6-11HR produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories