Rated for 110 CFM open-air (95.5 CFM at 0.25 in. w.g.), Broan AE110S = A000HSKT with AE110F1 registers #265 of 607 in quietness (1.0 sones) and delivers 4.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 95 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE110S = A000HSKT with AE110F1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 95.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 86.8% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE110S = A000HSKT with AE110F1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan AE110S = A000HSKT with AE110F1 (series: INVENT) under PD #4698014 (207 models registered, 2026-09-02). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).
How does Broan AE110S = A000HSKT with AE110F1 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE110S = A000HSKT with AE110F1 (1.0 sones).
How do flex elbows choke Broan AE110S = A000HSKT with AE110F1 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan AE110S = A000HSKT with AE110F1 moving full rated CFM.
Does Broan AE110S = A000HSKT with AE110F1 meet residential exhaust fan code specs?
Inspect Broan AE110S = A000HSKT with AE110F1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE110S = A000HSKT with AE110F1 / INVENT | PD ID 4698014 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan AE110S = A000HSKT with AE110F1 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan AE110S = A000HSKT with AE110F1 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Which competing models share Broan AE110S = A000HSKT with AE110F1 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Amazon Basics B089R8S365 | 110 / 94.3 CFM | 1.0 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7107-03HW | 110 / 96 CFM | 1.0 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Milano TY-110-E | 110 / 94.5 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Milano TY-110-ESHL | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Milano TY-110-ESL | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
How much airflow margin does Broan AE110S = A000HSKT with AE110F1 give your bath?
Run a quick local room-volume check for Broan AE110S = A000HSKT with AE110F1 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Broan AE110S = A000HSKT with AE110F1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE110S = A000HSKT with AE110F1.
Limitations & Who Should Skip
- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan AE110S = A000HSKT with AE110F1?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE110S = A000HSKT with AE110F1.
Is Broan AE110S = A000HSKT with AE110F1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE110S = A000HSKT with AE110F1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan AE110S = A000HSKT with AE110F1?
Do not force Broan AE110S = A000HSKT with AE110F1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan AE110S = A000HSKT with AE110F1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan AE110S = A000HSKT with AE110F1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Broan AE110S = A000HSKT with AE110F1 disturb adjacent bedrooms during night use?
Acoustic measurement places Broan AE110S = A000HSKT with AE110F1 at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Broan AE110S = A000HSKT with AE110F1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan AE110S = A000HSKT with AE110F1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan AE110S = A000HSKT with AE110F1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE110S = A000HSKT with AE110F1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE110S = A000HSKT with AE110F1?
Broan AE110S = A000HSKT with AE110F1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE110S = A000HSKT with AE110F1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE110S = A000HSKT with AE110F1's safe coverage footprint from 50 sq ft to 44 sq ft.