The Broan AE110SK = A000HSKT with AE110KF (INVENT) moves 110 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE110SK = A000HSKT with AE110KF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 95.5 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 86.8% @ 0.25"
- Motor Draw
- 25.6 W (9.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE110SK = A000HSKT with AE110KF vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan AE110SK = A000HSKT with AE110KF (series: INVENT) under PD #4697994 (207 models registered, 2026-09-02). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).
Where does Broan AE110SK = A000HSKT with AE110KF sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.
How does duct geometry alter Broan AE110SK = A000HSKT with AE110KF static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan AE110SK = A000HSKT with AE110KF?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE110SK = A000HSKT with AE110KF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE110SK = A000HSKT with AE110KF / INVENT | PD ID 4697994 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (95.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can Broan AE110SK = A000HSKT with AE110KF ventilate safely?
Sizing outputs below convert Broan AE110SK = A000HSKT with AE110KF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 95 sq ft | 1 CFM/sq ft @ 95.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 84 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 45 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 9.3 kWh/yr (~$1.49/yr) | 25.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 224.3 kWh/yr (~$35.89/yr) | 25.6 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan AE110SK = A000HSKT with AE110KF closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Amazon Basics B089R8S365 | 110 / 94.3 CFM | 1.0 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7107-03HW | 110 / 96 CFM | 1.0 sones (Same) | 4.1 CFM/W | 4 in. diameter |
| Milano TY-110-E | 110 / 94.5 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Milano TY-110-ESHL | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
| Milano TY-110-ESL | 110 / 94.2 CFM | 1.0 sones (Same) | 3.9 CFM/W | 4 in. diameter |
Will Broan AE110SK = A000HSKT with AE110KF clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan AE110SK = A000HSKT with AE110KF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
What plumbing or duct constraints rule out Broan AE110SK = A000HSKT with AE110KF?
Compare where Broan AE110SK = A000HSKT with AE110KF excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan AE110SK = A000HSKT with AE110KF?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE110SK = A000HSKT with AE110KF.
Why might a contractor swap Broan AE110SK = A000HSKT with AE110KF for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE110SK = A000HSKT with AE110KF lacks adequate reserve.
How does Broan AE110SK = A000HSKT with AE110KF handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE110SK = A000HSKT with AE110KF yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Broan AE110SK = A000HSKT with AE110KF quiet enough for a primary bedroom bathroom?
At 1.0 sones, Broan AE110SK = A000HSKT with AE110KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan AE110SK = A000HSKT with AE110KF energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan AE110SK = A000HSKT with AE110KF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE110SK = A000HSKT with AE110KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE110SK = A000HSKT with AE110KF?
Broan AE110SK = A000HSKT with AE110KF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE110SK = A000HSKT with AE110KF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE110SK = A000HSKT with AE110KF's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan AE110SK = A000HSKT with AE110KF serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan AE110SK = A000HSKT with AE110KF supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)