Skip to main content
Grant Estimator

Broan AE110SK = A000HSKT with AE110KF Exhaust Fan Specifications

ENERGY STAR PD #4697994 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

The Broan AE110SK = A000HSKT with AE110KF (INVENT) moves 110 CFM at 0.1 in. w.g. (95.5 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 4.3 CFM/W efficacy, sizing bathrooms up to 95 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE110SK = A000HSKT with AE110KF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
110 / 95.5 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
86.8% @ 0.25"
Motor Draw
25.6 W (9.3 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE110SK = A000HSKT with AE110KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 95.5 CFM out of 110 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE110SK = A000HSKT with AE110KF (series: INVENT) under PD #4697994 (207 models registered, 2026-09-02). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 25.6 watts, about 9.3 kWh/yr (~$1.49/yr at $0.16/kWh) for 1 hr/day shower timers or 224.3 kWh/yr (~$35.89/yr) continuously. Closest competing matches include Amazon Basics B089R8S365 (110.0 CFM) and HomeWerks Worldwide 7107-03HW (110.0 CFM).

Where does Broan AE110SK = A000HSKT with AE110KF sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How does duct geometry alter Broan AE110SK = A000HSKT with AE110KF static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan AE110SK = A000HSKT with AE110KF?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan AE110SK = A000HSKT with AE110KF alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE110SK = A000HSKT with AE110KF / INVENT PD ID 4697994 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (95.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Broan AE110SK = A000HSKT with AE110KF ventilate safely?

Sizing outputs below convert Broan AE110SK = A000HSKT with AE110KF tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan AE110SK = A000HSKT with AE110KF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 95 sq ft1 CFM/sq ft @ 95.5 CFM
Tall Bath (9-ft Ceiling)Up to 84 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 45 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.3 kWh/yr (~$1.49/yr)25.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2224.3 kWh/yr (~$35.89/yr)25.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan AE110SK = A000HSKT with AE110KF closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Amazon Basics B089R8S365 110 / 94.3 CFM 1.0 sones (Same) 4.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7107-03HW 110 / 96 CFM 1.0 sones (Same) 4.1 CFM/W 4 in. diameter
Milano TY-110-E 110 / 94.5 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESHL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter

Will Broan AE110SK = A000HSKT with AE110KF clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan AE110SK = A000HSKT with AE110KF satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

What plumbing or duct constraints rule out Broan AE110SK = A000HSKT with AE110KF?

Compare where Broan AE110SK = A000HSKT with AE110KF excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 45 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 95 sq ft with 8-ft ceilings (84 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Broan AE110SK = A000HSKT with AE110KF?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan AE110SK = A000HSKT with AE110KF.

Why might a contractor swap Broan AE110SK = A000HSKT with AE110KF for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE110SK = A000HSKT with AE110KF lacks adequate reserve.

How does Broan AE110SK = A000HSKT with AE110KF handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE110SK = A000HSKT with AE110KF yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Broan AE110SK = A000HSKT with AE110KF quiet enough for a primary bedroom bathroom?

At 1.0 sones, Broan AE110SK = A000HSKT with AE110KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan AE110SK = A000HSKT with AE110KF energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan AE110SK = A000HSKT with AE110KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE110SK = A000HSKT with AE110KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE110SK = A000HSKT with AE110KF?

Broan AE110SK = A000HSKT with AE110KF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE110SK = A000HSKT with AE110KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE110SK = A000HSKT with AE110KF's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan AE110SK = A000HSKT with AE110KF serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE110SK = A000HSKT with AE110KF supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)