Tested under HVI protocols, the Broan AE80S = A000HFS with AE80F1 exhaust unit achieves 80 CFM at 0.1 in. w.g. (70.6 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 70 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80S = A000HFS with AE80F1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 70.6 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 88.2% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80S = A000HFS with AE80F1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.6 CFM out of 80 CFM (88.2% retention, 0.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2369233 verifies AE80S = A000HFS with AE80F1 (series: INVENT) under Broan (207 listed models, qualified 2020-11-06). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include ACIQ AEP80 (80.0 CFM) and Canarm CEP80 (80.0 CFM).
Where do Broan AE80S = A000HFS with AE80F1 sones rank across EPA ENERGY STAR fans?
Comparing Broan AE80S = A000HFS with AE80F1 (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan AE80S = A000HFS with AE80F1 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE80S = A000HFS with AE80F1, preventing premature peeling paint and mold growth.
How does Broan AE80S = A000HFS with AE80F1 measure up on airflow and noise ratings?
Each row below breaks down Broan AE80S = A000HFS with AE80F1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80S = A000HFS with AE80F1 / INVENT | PD ID 2369233 (Qualified 2020-11-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan AE80S = A000HFS with AE80F1 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan AE80S = A000HFS with AE80F1?
Compare Broan AE80S = A000HFS with AE80F1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Revent RVPR80 | 80 / 66.2 CFM | 0.7 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Can you size Broan AE80S = A000HFS with AE80F1 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE80S = A000HFS with AE80F1 verified capacity.
Does Broan AE80S = A000HFS with AE80F1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan AE80S = A000HFS with AE80F1 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 70.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 0.7 sones up to 70 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Broan AE80S = A000HFS with AE80F1?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE80S = A000HFS with AE80F1.
What acoustic sone tier does Broan AE80S = A000HFS with AE80F1 occupy in EPA filings?
With 0.7 sones at 0.1 in. w.g., Broan AE80S = A000HFS with AE80F1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Broan AE80S = A000HFS with AE80F1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan AE80S = A000HFS with AE80F1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan AE80S = A000HFS with AE80F1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80S = A000HFS with AE80F1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80S = A000HFS with AE80F1?
Broan AE80S = A000HFS with AE80F1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80S = A000HFS with AE80F1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80S = A000HFS with AE80F1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan AE80S = A000HFS with AE80F1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan AE80S = A000HFS with AE80F1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan AE80S = A000HFS with AE80F1 in a bathroom remodel?
Avoid specifying Broan AE80S = A000HFS with AE80F1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan AE80S = A000HFS with AE80F1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan AE80S = A000HFS with AE80F1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)