Skip to main content
Grant Estimator

Broan AE80SK = A000HSKT with AE80KF Exhaust Fan Specifications

ENERGY STAR PD #4697755 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Tested under HVI protocols, the Broan AE80SK = A000HSKT with AE80KF exhaust unit achieves 80 CFM at 0.1 in. w.g. (70.6 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 70 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80SK = A000HSKT with AE80KF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 70.6 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
88.2% @ 0.25"
Motor Draw
20.5 W (7.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80SK = A000HSKT with AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.6 CFM out of 80 CFM (88.2% retention, 0.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU AE80SK = A000HSKT with AE80KF (series: INVENT) (PD #4697755) certified since 2026-09-02. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include ACIQ AEP80 (80.0 CFM) and Canarm CEP80 (80.0 CFM).

Where do Broan AE80SK = A000HSKT with AE80KF sones rank across EPA ENERGY STAR fans?

Comparing Broan AE80SK = A000HSKT with AE80KF (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

What attic duct routing preserves Broan AE80SK = A000HSKT with AE80KF CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE80SK = A000HSKT with AE80KF, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan AE80SK = A000HSKT with AE80KF measure up on airflow and noise ratings?

Each row below breaks down Broan AE80SK = A000HSKT with AE80KF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80SK = A000HSKT with AE80KF / INVENT PD ID 4697755 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (70.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan AE80SK = A000HSKT with AE80KF CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan AE80SK = A000HSKT with AE80KF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 70 sq ft1 CFM/sq ft @ 70.6 CFM
Tall Bath (9-ft Ceiling)Up to 62 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 20 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2179.6 kWh/yr (~$28.74/yr)20.5 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan AE80SK = A000HSKT with AE80KF?

Compare Broan AE80SK = A000HSKT with AE80KF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AEP80 80 / 70.9 CFM 0.7 sones (Same) 4.2 CFM/W 6 in. diameter
Canarm CEP80 80 / 70.9 CFM 0.7 sones (Same) 4.2 CFM/W 6 in. diameter
Cyclone ESCBP80 80 / 70.9 CFM 0.7 sones (Same) 4.2 CFM/W 6 in. diameter
Revent RVPR80 80 / 66.2 CFM 0.7 sones (Same) 4.2 CFM/W 4 in. diameter
Ortech ODE-8007 80 / 69.8 CFM 0.7 sones (Same) 4.3 CFM/W 4 in. diameter

Can you size Broan AE80SK = A000HSKT with AE80KF for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE80SK = A000HSKT with AE80KF verified capacity.

When does Broan AE80SK = A000HSKT with AE80KF fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan AE80SK = A000HSKT with AE80KF.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 70.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 0.7 sones up to 70 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan AE80SK = A000HSKT with AE80KF?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE80SK = A000HSKT with AE80KF.

Which bathroom layouts should pick a larger blower than Broan AE80SK = A000HSKT with AE80KF?

Do not force Broan AE80SK = A000HSKT with AE80KF into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan AE80SK = A000HSKT with AE80KF retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan AE80SK = A000HSKT with AE80KF produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Broan AE80SK = A000HSKT with AE80KF disturb adjacent bedrooms during night use?

Acoustic measurement places Broan AE80SK = A000HSKT with AE80KF at 0.7 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Broan AE80SK = A000HSKT with AE80KF continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan AE80SK = A000HSKT with AE80KF draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan AE80SK = A000HSKT with AE80KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80SK = A000HSKT with AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80SK = A000HSKT with AE80KF?

Broan AE80SK = A000HSKT with AE80KF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80SK = A000HSKT with AE80KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80SK = A000HSKT with AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan AE80SK = A000HSKT with AE80KF code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan AE80SK = A000HSKT with AE80KF clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories