In EPA dataset 8dv7-nngq, Broan ALT3304WW tests at 160 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 3.8 CFM/W efficacy, meeting residential IRC M1505 sizing up to 160 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan ALT3304WW Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 42.1 W (15.4 kWh/yr)
- Duct & Tier
- 3.25 x 10 in. rectangular · Standard

What does Broan ALT3304WW vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan ALT3304WW (EPA filing PD #3998906) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.
Broan maintains 207 active ENERGY STAR blowers; ALT3304WW (series: RANGE HOOD) (PD #3998906) gained qualification on 2025-02-21. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 42.1 watts, about 15.4 kWh/yr (~$2.46/yr at $0.16/kWh) for 1 hr/day shower timers or 368.8 kWh/yr (~$59.01/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan ALT4306SS (160.0 CFM).
Why avoid unvented attic termination with Broan ALT3304WW?
Under ASHRAE 62.2 best practice, Broan ALT3304WW needs insulated 3.25 x 10 in. rectangular rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan ALT3304WW?
Before cutting ceiling drywall or sizing attic transitions for Broan ALT3304WW, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ALT3304WW / RANGE HOOD | PD ID 3998906 (Qualified 2025-02-21) |
| Duct Connection | 3.25 x 10 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (160 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan ALT3304WW?
Bathroom ventilation sizing below maps Broan ALT3304WW motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 160 sq ft | 1 CFM/sq ft @ 160 CFM |
| Tall Bath (9-ft Ceiling) | Up to 142 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 110 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 15.4 kWh/yr (~$2.46/yr) | 42.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 368.8 kWh/yr (~$59.01/yr) | 42.1 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan ALT3304WW in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan ALT3304WW.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Best UCB3I30BLSB | 160 / N/A CFM | Unpublished | 3.2 CFM/W | 3.25 in. diameter |
What percentage of room demand does Broan ALT3304WW cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan ALT3304WW tested delivery.
What plumbing or duct constraints rule out Broan ALT3304WW?
Compare where Broan ALT3304WW excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 160 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 160 sq ft
- Suited to: Paired with rigid galvanized 3.25 x 10 in. rectangular transition
Where do official rules set limits for Broan ALT3304WW?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan ALT3304WW.
Is Broan ALT3304WW quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Broan ALT3304WW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan ALT3304WW energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan ALT3304WW pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan ALT3304WW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan ALT3304WW?
Broan ALT3304WW features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan ALT3304WW's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan ALT3304WW's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan ALT3304WW serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan ALT3304WW supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Broan ALT3304WW for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan ALT3304WW lacks adequate reserve.
How does Broan ALT3304WW handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan ALT3304WW yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3.25 x 10 in. rectangular rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)