Skip to main content
Grant Estimator

Broan BWPR302SSE Exhaust Fan Specifications

ENERGY STAR PD #4694714 · Range Hood · Qualified 2026-08-19
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan BWPR302SSE tests at 120 CFM free discharge (unpublished 0.25 in. w.g. output) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 120 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan BWPR302SSE Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.2 CFM/W (#1,091/1,145)
Static Retention
0.1" test only
Motor Draw
37.5 W (13.7 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan BWPR302SSE vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places BWPR302SSE (series: RANGE HOOD) (PD #4694714) among 207 Broan entries qualified through 2026-08-19. Lighting kit: Yes. At 3.2 CFM/W (#1,091 of 1,145, below median tier among 1,145 rated models; more efficient than 4.0% of rated models, 1.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 37.5 watts, about 13.7 kWh/yr (~$2.19/yr at $0.16/kWh) for 1 hr/day shower timers or 328.5 kWh/yr (~$52.56/yr) continuously. Closest competing matches include Ortech OD-1209PB (120.0 CFM) and Milano TY-110-E (110.0 CFM).

Does Broan BWPR302SSE fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan BWPR302SSE at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Broan BWPR302SSE?

Under ASHRAE 62.2 best practice, Broan BWPR302SSE needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan BWPR302SSE?

Before cutting ceiling drywall or sizing attic transitions for Broan BWPR302SSE, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series BWPR302SSE / RANGE HOOD PD ID 4694714 (Qualified 2026-08-19)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Broan BWPR302SSE?

Bathroom ventilation sizing below maps Broan BWPR302SSE motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan BWPR302SSE
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)13.7 kWh/yr (~$2.19/yr)37.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2328.5 kWh/yr (~$52.56/yr)37.5 W x 8,760 hrs / 1,000

What peer models sit nearest Broan BWPR302SSE in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan BWPR302SSE.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech OD-1209PB 120 / 101.6 CFM 0.9 sones (-0.10) 4.3 CFM/W 6 in. diameter
Milano TY-110-E 110 / 94.5 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESHL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
HomeWerks Worldwide 7107-03HW 110 / 96 CFM 1.0 sones (Same) 4.1 CFM/W 4 in. diameter

What percentage of room demand does Broan BWPR302SSE cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan BWPR302SSE tested delivery.

What plumbing or duct constraints rule out Broan BWPR302SSE?

Compare where Broan BWPR302SSE excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 120 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 1.0 sones up to 120 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan BWPR302SSE?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan BWPR302SSE.

Can Broan BWPR302SSE serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan BWPR302SSE supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Broan BWPR302SSE for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan BWPR302SSE lacks adequate reserve.

How does Broan BWPR302SSE handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan BWPR302SSE yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Broan BWPR302SSE quiet enough for a primary bedroom bathroom?

At 1.0 sones, Broan BWPR302SSE operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan BWPR302SSE energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan BWPR302SSE pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan BWPR302SSE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan BWPR302SSE?

Broan BWPR302SSE features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan BWPR302SSE's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan BWPR302SSE's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories