Skip to main content
Grant Estimator

Broan WPR302CSSE Exhaust Fan Specifications

ENERGY STAR PD #4623514 · Range Hood · Qualified 2026-05-06
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan WPR302CSSE tests at 120 CFM free discharge (unpublished 0.25 in. w.g. output) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 120 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan WPR302CSSE Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.2 CFM/W (#1,091/1,145)
Static Retention
0.1" test only
Motor Draw
37.5 W (13.7 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan WPR302CSSE vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Broan maintains 207 active ENERGY STAR blowers; WPR302CSSE (series: RANGE HOOD) (PD #4623514) gained qualification on 2026-05-06. Lighting kit: Yes. At 3.2 CFM/W (#1,091 of 1,145, below median tier among 1,145 rated models; more efficient than 4.0% of rated models, 1.5 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 37.5 watts, about 13.7 kWh/yr (~$2.19/yr at $0.16/kWh) for 1 hr/day shower timers or 328.5 kWh/yr (~$52.56/yr) continuously. Closest competing matches include Ortech OD-1209PB (120.0 CFM) and Milano TY-110-E (110.0 CFM).

Does Broan WPR302CSSE fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan WPR302CSSE at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Broan WPR302CSSE?

Under ASHRAE 62.2 best practice, Broan WPR302CSSE needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan WPR302CSSE?

Before cutting ceiling drywall or sizing attic transitions for Broan WPR302CSSE, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series WPR302CSSE / RANGE HOOD PD ID 4623514 (Qualified 2026-05-06)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Broan WPR302CSSE?

Bathroom ventilation sizing below maps Broan WPR302CSSE motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan WPR302CSSE
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)13.7 kWh/yr (~$2.19/yr)37.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2328.5 kWh/yr (~$52.56/yr)37.5 W x 8,760 hrs / 1,000

What peer models sit nearest Broan WPR302CSSE in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan WPR302CSSE.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Ortech OD-1209PB 120 / 101.6 CFM 0.9 sones (-0.10) 4.3 CFM/W 6 in. diameter
Milano TY-110-E 110 / 94.5 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESHL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
Milano TY-110-ESL 110 / 94.2 CFM 1.0 sones (Same) 3.9 CFM/W 4 in. diameter
HomeWerks Worldwide 7107-03HW 110 / 96 CFM 1.0 sones (Same) 4.1 CFM/W 4 in. diameter

What percentage of room demand does Broan WPR302CSSE cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan WPR302CSSE tested delivery.

Which bath layouts should avoid specifying Broan WPR302CSSE?

Match Broan WPR302CSSE directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 120 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 1.0 sones up to 120 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan WPR302CSSE?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan WPR302CSSE.

Where does Broan WPR302CSSE sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, Broan WPR302CSSE operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Broan WPR302CSSE cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan WPR302CSSE 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Broan WPR302CSSE pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan WPR302CSSE's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan WPR302CSSE?

Broan WPR302CSSE features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan WPR302CSSE's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan WPR302CSSE's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Broan WPR302CSSE ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan WPR302CSSE covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Broan WPR302CSSE run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan WPR302CSSE.

What happens to Broan WPR302CSSE CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan WPR302CSSE moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories