Certified by EPA ENERGY STAR, Broan (Canada) EZ80C delivers 70 CFM free-air (60.5 CFM at 0.25 in. w.g.) and registers #397 of 607 in quietness (1.3 sones) and delivers 3.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 60 sq ft (8-ft height) or 53 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan (Canada) EZ80C Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 70 / 60.5 CFM
- Noise @ 0.1"
- 1.3 sones (#397/607)
- Efficacy Rank
- 3.4 CFM/W (#1,060/1,145)
- Static Retention
- 86.4% @ 0.25"
- Motor Draw
- 20.6 W (7.5 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Broan (Canada) EZ80C vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2406835 verifies EZ80C (series: EZ FIT) under Broan (Canada) (3 listed models, qualified 2023-01-13). Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Nutone LPN80=LP80HwithLPN80F (70.0 CFM) and Air King LEDAK80 (80.0 CFM).
How noisy is Broan (Canada) EZ80C compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Broan (Canada) EZ80C measures 1.3 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect Broan (Canada) EZ80C airflow?
Connecting Broan (Canada) EZ80C through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan (Canada) EZ80C performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan (Canada) EZ80C lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (Canada) (3 models) | ENERGY STAR Certified Partner |
| Model Number & Series | EZ80C / EZ FIT | PD ID 2406835 (Qualified 2023-01-13) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.3 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan (Canada) EZ80C?
Calculated coverage metrics translate Broan (Canada) EZ80C airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 180.5 kWh/yr (~$28.88/yr) | 20.6 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan (Canada) EZ80C?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Nutone LPN80=LP80HwithLPN80F | 70 / 60.5 CFM | 1.3 sones (Same) | 3.4 CFM/W | 3 in. diameter |
| Air King LEDAK80 | 80 / 70.3 CFM | 1.2 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Broan EZ80 | 70 / 60.5 CFM | 1.1 sones (-0.20) | 3.4 CFM/W | 3 in. diameter |
| Broan LP80 | 70 / 60.5 CFM | 1.1 sones (-0.20) | 3.4 CFM/W | 3 in. diameter |
| Broan LP80=LP80HwithLP80F | 70 / 60.5 CFM | 1.1 sones (-0.20) | 3.4 CFM/W | 3 in. diameter |
Does Broan (Canada) EZ80C match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan (Canada) EZ80C percentage capacity without sending data.
What plumbing or duct constraints rule out Broan (Canada) EZ80C?
Compare where Broan (Canada) EZ80C excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 60.5 CFM net static output
- Suited to: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan (Canada) EZ80C?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan (Canada) EZ80C.
Can Broan (Canada) EZ80C serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan (Canada) EZ80C supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Broan (Canada) EZ80C for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan (Canada) EZ80C lacks adequate reserve.
How does Broan (Canada) EZ80C handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan (Canada) EZ80C yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.
Is Broan (Canada) EZ80C quiet enough for a primary bedroom bathroom?
At 1.3 sones, Broan (Canada) EZ80C produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan (Canada) EZ80C energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan (Canada) EZ80C pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan (Canada) EZ80C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan (Canada) EZ80C?
Broan (Canada) EZ80C features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan (Canada) EZ80C's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan (Canada) EZ80C's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)