Skip to main content
Grant Estimator

Nutone LPN80=LP80HwithLPN80F Exhaust Fan Specifications

ENERGY STAR PD #2341168 · Bathroom/Utility Room · Qualified 2015-10-01
Verified Specification Summary

Homeowners specifying Nutone LPN80=LP80HwithLPN80F gain 70 CFM at 0.1 in. w.g. (60.5 CFM at 0.25 in. w.g.) where it registers #397 of 607 in quietness (1.3 sones) and delivers 3.4 CFM/W efficacy, venting bathrooms up to 60 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone LPN80=LP80HwithLPN80F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 60.5 CFM
Noise @ 0.1"
1.3 sones (#397/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
86.4% @ 0.25"
Motor Draw
20.6 W (7.5 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Nutone LPN80=LP80HwithLPN80F vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.3 sones (#397 of 607 rated models, 0.30 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Nutone's 16-unit lineup, LPN80=LP80HwithLPN80F (series: N/A) carries PD #2341168 dating to 2015-10-01. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Broan (Canada) EZ80C (70.0 CFM) and Air King LEDAK80 (80.0 CFM).

What acoustic percentile does Nutone LPN80=LP80HwithLPN80F occupy among 1,145 bath blowers?

Inspect how Nutone LPN80=LP80HwithLPN80F positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.3 sone: 1.3 sones (67th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.3 sone: 1.3 sones (P67)

Which exterior damper path suits Nutone LPN80=LP80HwithLPN80F best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Nutone LPN80=LP80HwithLPN80F housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Nutone LPN80=LP80HwithLPN80F acoustic and static metrics stand?

Compare Nutone LPN80=LP80HwithLPN80F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Nutone (16 models) ENERGY STAR Certified Partner
Model Number & Series LPN80=LP80HwithLPN80F / N/A PD ID 2341168 (Qualified 2015-10-01)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.3 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Nutone LPN80=LP80HwithLPN80F handle taller ceilings or walk-in tub steam?

Evaluate how Nutone LPN80=LP80HwithLPN80F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Nutone LPN80=LP80HwithLPN80F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.5 CFM
Tall Bath (9-ft Ceiling)Up to 53 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2180.5 kWh/yr (~$28.88/yr)20.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Nutone LPN80=LP80HwithLPN80F?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan (Canada) EZ80C 70 / 60.5 CFM 1.3 sones (Same) 3.4 CFM/W 3 in. diameter
Air King LEDAK80 80 / 70.3 CFM 1.2 sones (-0.10) 3.5 CFM/W 4 in. diameter
Broan EZ80 70 / 60.5 CFM 1.1 sones (-0.20) 3.4 CFM/W 3 in. diameter
Broan LP80 70 / 60.5 CFM 1.1 sones (-0.20) 3.4 CFM/W 3 in. diameter
Broan LP80=LP80HwithLP80F 70 / 60.5 CFM 1.1 sones (-0.20) 3.4 CFM/W 3 in. diameter

Is Nutone LPN80=LP80HwithLPN80F sized right for your shower or tub room?

Check whether Nutone LPN80=LP80HwithLPN80F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Does Nutone LPN80=LP80HwithLPN80F suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Nutone LPN80=LP80HwithLPN80F for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 60.5 CFM net static output
  • Best application: Collar pairs with 3 in. diameter duct straight outdoors

Which code checks and cost facts matter for Nutone LPN80=LP80HwithLPN80F?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Nutone LPN80=LP80HwithLPN80F.

Does Nutone LPN80=LP80HwithLPN80F pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Nutone LPN80=LP80HwithLPN80F easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Nutone LPN80=LP80HwithLPN80F in a bathroom remodel?

Avoid specifying Nutone LPN80=LP80HwithLPN80F in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Nutone LPN80=LP80HwithLPN80F airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Nutone LPN80=LP80HwithLPN80F achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Nutone LPN80=LP80HwithLPN80F occupy in EPA filings?

With 1.3 sones at 0.1 in. w.g., Nutone LPN80=LP80HwithLPN80F produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Nutone LPN80=LP80HwithLPN80F add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Nutone LPN80=LP80HwithLPN80F averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Nutone LPN80=LP80HwithLPN80F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone LPN80=LP80HwithLPN80F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Nutone LPN80=LP80HwithLPN80F?

Nutone LPN80=LP80HwithLPN80F features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Nutone LPN80=LP80HwithLPN80F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone LPN80=LP80HwithLPN80F's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories