Skip to main content
Grant Estimator

Broan GLA1363WW Exhaust Fan Specifications

ENERGY STAR PD #3945289 · Range Hood · Qualified 2025-01-24
Verified Specification Summary

Tested under HVI protocols, the Broan GLA1363WW exhaust unit achieves 150 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, covering standard baths up to 150 sq ft on a 7 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan GLA1363WW Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.6 CFM/W (#578/1,145)
Static Retention
0.1" test only
Motor Draw
32.6 W (11.9 kWh/yr)
Duct & Tier
7 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan GLA1363WW vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan GLA1363WW (EPA filing PD #3945289) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan maintains 207 active ENERGY STAR blowers; GLA1363WW (series: RANGE HOOD) (PD #3945289) gained qualification on 2025-01-24. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).

What attic duct routing preserves Broan GLA1363WW CFM output?

Short straight 7 in. diameter duct paths retain up to ~82% of open-air capacity on Broan GLA1363WW, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan GLA1363WW measure up on airflow and noise ratings?

Each row below breaks down Broan GLA1363WW certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series GLA1363WW / RANGE HOOD PD ID 3945289 (Qualified 2025-01-24)
Duct Connection 7 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (150 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Broan GLA1363WW CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan GLA1363WW
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 150 sq ft1 CFM/sq ft @ 150 CFM
Tall Bath (9-ft Ceiling)Up to 133 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 100 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)11.9 kWh/yr (~$1.90/yr)32.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2285.6 kWh/yr (~$45.70/yr)32.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan GLA1363WW?

Compare Broan GLA1363WW side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter

Can you size Broan GLA1363WW for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan GLA1363WW verified capacity.

Does Broan GLA1363WW suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan GLA1363WW for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 150 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 150 sq ft
  • Best application: Paired with rigid galvanized 7 in. diameter transition

How do federal and code standards apply to Broan GLA1363WW?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan GLA1363WW.

How many kWh per year does Broan GLA1363WW add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan GLA1363WW averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan GLA1363WW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan GLA1363WW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan GLA1363WW?

Broan GLA1363WW features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan GLA1363WW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan GLA1363WW's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan GLA1363WW pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan GLA1363WW easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan GLA1363WW in a bathroom remodel?

Avoid specifying Broan GLA1363WW in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan GLA1363WW airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan GLA1363WW achieves unlisted 0.25 in. w.g. backpressure figures; matching a 7 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan GLA1363WW occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Broan GLA1363WW produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories