Certified by EPA ENERGY STAR, Broan GLA2363BLS delivers 150 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.6 CFM/W efficacy, clearing residential IRC M1505 sizing up to 150 sq ft (8-ft height) or 133 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan GLA2363BLS Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.6 CFM/W (#578/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 32.6 W (11.9 kWh/yr)
- Duct & Tier
- 7 in. diameter · Standard

What does Broan GLA2363BLS vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan GLA2363BLS (EPA filing PD #3984074) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 150 CFM (#104 of 1,145 certified models) via a 7 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 7 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Broan maintains 207 active ENERGY STAR blowers; GLA2363BLS (series: RANGE HOOD) (PD #3984074) gained qualification on 2025-01-24. Lighting kit: Yes. At 4.6 CFM/W (#578 of 1,145, below median tier among 1,145 rated models; more efficient than 44.9% of rated models, 0.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 32.6 watts, about 11.9 kWh/yr (~$1.90/yr at $0.16/kWh) for 1 hr/day shower timers or 285.6 kWh/yr (~$45.70/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Loren Cook Company GC-242 (142.0 CFM).
Why does rigid 7 in. diameter ducting protect Broan GLA2363BLS airflow?
Connecting Broan GLA2363BLS through rigid 7 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan GLA2363BLS performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan GLA2363BLS lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | GLA2363BLS / RANGE HOOD | PD ID 3984074 (Qualified 2025-01-24) |
| Duct Connection | 7 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (150 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan GLA2363BLS?
Calculated coverage metrics translate Broan GLA2363BLS airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 150 sq ft | 1 CFM/sq ft @ 150 CFM |
| Tall Bath (9-ft Ceiling) | Up to 133 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 100 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 11.9 kWh/yr (~$1.90/yr) | 32.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 285.6 kWh/yr (~$45.70/yr) | 32.6 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan GLA2363BLS?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Nutone QTN130LE1 | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
Does Broan GLA2363BLS match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan GLA2363BLS percentage capacity without sending data.
What plumbing or duct constraints rule out Broan GLA2363BLS?
Compare where Broan GLA2363BLS excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 100 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 150 CFM net static output
- Suited to: Collar pairs with 7 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan GLA2363BLS?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan GLA2363BLS.
How does Broan GLA2363BLS handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan GLA2363BLS yields unlisted 0.25 in. w.g. backpressure figures, so smooth 7 in. diameter rigid metal ducting protects real exhaust.
Is Broan GLA2363BLS quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Broan GLA2363BLS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan GLA2363BLS energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan GLA2363BLS pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan GLA2363BLS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan GLA2363BLS?
Broan GLA2363BLS features a 7 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan GLA2363BLS's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan GLA2363BLS's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan GLA2363BLS serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan GLA2363BLS supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Broan GLA2363BLS for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan GLA2363BLS lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)