Broan-Nutone LP510RSR Exhaust Fan Specifications

ENERGY STAR PD #4682894 · Bathroom/Utility Room · Qualified 2026-08-05
Verified Specification Summary

Rated for 100 CFM open-air (99 CFM at 0.25 in. w.g.), Broan-Nutone LP510RSR omits a published 0.1-inch sone rating and delivers 9.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 99 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone LP510RSR Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 99 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.6 CFM/W (#206/1,145)
Static Retention
99.0% @ 0.25"
Motor Draw
10.4 W (3.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone LP510RSR vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone LP510RSR (EPA filing PD #4682894) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 99 CFM out of 100 CFM (99.0% retention, 11.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Broan-Nutone maintains 48 active ENERGY STAR blowers; LP510RSR (series: LP510RSR) (PD #4682894) gained qualification on 2026-08-05. Lighting kit: No. At 9.6 CFM/W (#206 of 1,145, top 20.3% of 1,145 rated models, more efficient than 79.7% of rated models, 4.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.4 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 91.1 kWh/yr (~$14.58/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How do flex elbows choke Broan-Nutone LP510RSR at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan-Nutone LP510RSR moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan-Nutone LP510RSR meet residential exhaust fan code specs?

Inspect Broan-Nutone LP510RSR mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series LP510RSR / LP510RSR PD ID 4682894 (Qualified 2026-08-05)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (99 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Broan-Nutone LP510RSR airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone LP510RSR tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan-Nutone LP510RSR
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 99 sq ft1 CFM/sq ft @ 99 CFM
Tall Bath (9-ft Ceiling)Up to 88 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 49 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.8 kWh/yr (~$0.61/yr)10.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.291.1 kWh/yr (~$14.58/yr)10.4 W x 8,760 hrs / 1,000

Which competing models share Broan-Nutone LP510RSR airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta GBR100LED-DECOR 100 / 75 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Delta 100HS 100 / 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Broan-Nutone LP510RSR give your bath?

Run a quick local room-volume check for Broan-Nutone LP510RSR by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Broan-Nutone LP510RSR on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone LP510RSR carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 49 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 99 sq ft with 8-ft ceilings (88 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Broan-Nutone LP510RSR?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone LP510RSR.

How does Broan-Nutone LP510RSR score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone LP510RSR delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan-Nutone LP510RSR?

Rule out Broan-Nutone LP510RSR when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan-Nutone LP510RSR capacity?

Because static drag at 0.25 in. w.g. lowers Broan-Nutone LP510RSR from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan-Nutone LP510RSR compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Broan-Nutone LP510RSR produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan-Nutone LP510RSR consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan-Nutone LP510RSR draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan-Nutone LP510RSR pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone LP510RSR's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone LP510RSR?

Broan-Nutone LP510RSR features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone LP510RSR's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone LP510RSR's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories