Skip to main content
Grant Estimator

Broan-Nutone PTEL511RK Exhaust Fan Specifications

ENERGY STAR PD #4191424 · Bathroom/Utility Room · Qualified 2025-05-23
Verified Specification Summary

The Broan-Nutone PTEL511RK (PREMIUM) moves 110 CFM at 0.1 in. w.g. (110.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 14.5 CFM/W efficacy, sizing bathrooms up to 110 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTEL511RK Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 110.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
14.5 CFM/W (#29/1,145)
Static Retention
100.7% @ 0.25"
Motor Draw
7.6 W (2.8 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone PTEL511RK vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PTEL511RK (EPA filing PD #4191424) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.8 CFM out of 110 CFM (100.7% retention, 13.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan-Nutone's 48-unit lineup, PTEL511RK (series: PREMIUM) carries PD #4191424 dating to 2025-05-23. Lighting kit: Yes. At 14.5 CFM/W (#29 of 1,145, top 2.8% of 1,145 rated models, more efficient than 97.2% of rated models, 9.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How does duct geometry alter Broan-Nutone PTEL511RK static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan-Nutone PTEL511RK?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan-Nutone PTEL511RK alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series PTEL511RK / PREMIUM PD ID 4191424 (Qualified 2025-05-23)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Broan-Nutone PTEL511RK ventilate safely?

Sizing outputs below convert Broan-Nutone PTEL511RK tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PTEL511RK
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.8 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.266.6 kWh/yr (~$10.66/yr)7.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan-Nutone PTEL511RK closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Broan PTE511RKY 110 / 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Panasonic FV-0511VKS3S 110 / 111.9 CFM Unpublished 15.1 CFM/W 6 in. diameter
Delta SIG80-110 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter

Will Broan-Nutone PTEL511RK clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan-Nutone PTEL511RK satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install Broan-Nutone PTEL511RK in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone PTEL511RK for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 110 sq ft with 8-ft ceilings (98 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Broan-Nutone PTEL511RK?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan-Nutone PTEL511RK.

When is Broan-Nutone PTEL511RK undersized or poorly matched for a bath renovation?

Skip Broan-Nutone PTEL511RK if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan-Nutone PTEL511RK CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone PTEL511RK registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Broan-Nutone PTEL511RK sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan-Nutone PTEL511RK produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan-Nutone PTEL511RK?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan-Nutone PTEL511RK pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTEL511RK's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone PTEL511RK?

Broan-Nutone PTEL511RK features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone PTEL511RK's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTEL511RK's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone PTEL511RK satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTEL511RK clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories