Broan PTE511RKY Exhaust Fan Specifications

ENERGY STAR PD #4529606 · Bathroom/Utility Room · Qualified 2026-02-11
Verified Specification Summary

The Broan PTE511RKY (EVOLVE) moves 110 CFM at 0.1 in. w.g. (110.8 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 14.5 CFM/W efficacy, sizing bathrooms up to 110 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan PTE511RKY Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 110.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
14.5 CFM/W (#29/1,145)
Static Retention
100.7% @ 0.25"
Motor Draw
7.6 W (2.8 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan PTE511RKY vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan PTE511RKY (EPA filing PD #4529606) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.8 CFM out of 110 CFM (100.7% retention, 13.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan's 207-unit lineup, PTE511RKY (series: EVOLVE) carries PD #4529606 dating to 2026-02-11. Lighting kit: No. At 14.5 CFM/W (#29 of 1,145, top 2.8% of 1,145 rated models, more efficient than 97.2% of rated models, 9.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How does duct geometry alter Broan PTE511RKY static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan PTE511RKY?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan PTE511RKY alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series PTE511RKY / EVOLVE PD ID 4529606 (Qualified 2026-02-11)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Broan PTE511RKY ventilate safely?

Sizing outputs below convert Broan PTE511RKY tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan PTE511RKY
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.8 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.266.6 kWh/yr (~$10.66/yr)7.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan PTE511RKY closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Broan-Nutone PTE511RK 110 / 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan-Nutone PTE511RK = PTE511H with PTE511RKF 110 / 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan-Nutone PTEL511RK 110 / 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter

Will Broan PTE511RKY clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan PTE511RKY satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Who should not install Broan PTE511RKY in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan PTE511RKY for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 110 sq ft with 8-ft ceilings (98 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Broan PTE511RKY?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan PTE511RKY.

When is Broan PTE511RKY undersized or poorly matched for a bath renovation?

Skip Broan PTE511RKY if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Broan PTE511RKY CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan PTE511RKY registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 in. diameter duct runs vital.

How does Broan PTE511RKY sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Broan PTE511RKY produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan PTE511RKY?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan PTE511RKY pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan PTE511RKY's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan PTE511RKY?

Broan PTE511RKY features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan PTE511RKY's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan PTE511RKY's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan PTE511RKY satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan PTE511RKY clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories