Skip to main content
Grant Estimator

Broan-Nutone PTE511RK = PTE511H with PTE511RKF Exhaust Fan Specifications

ENERGY STAR PD #4191418 · Bathroom/Utility Room · Qualified 2025-05-23
Verified Specification Summary

Certified by EPA ENERGY STAR, Broan-Nutone PTE511RK = PTE511H with PTE511RKF delivers 110 CFM free-air (110.8 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 14.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 110 sq ft (8-ft height) or 98 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTE511RK = PTE511H with PTE511RKF Exhaust before installation.

Airflow @ 0.1" / 0.25"
110 / 110.8 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
14.5 CFM/W (#29/1,145)
Static Retention
100.7% @ 0.25"
Motor Draw
7.6 W (2.8 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone PTE511RK = PTE511H with PTE511RKF vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan-Nutone PTE511RK = PTE511H with PTE511RKF (EPA filing PD #4191418) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 110.8 CFM out of 110 CFM (100.7% retention, 13.0 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Broan-Nutone PTE511RK = PTE511H with PTE511RKF (series: PREMIUM) under PD #4191418 (48 models registered, 2025-05-23). Lighting kit: No. At 14.5 CFM/W (#29 of 1,145, top 2.8% of 1,145 rated models, more efficient than 97.2% of rated models, 9.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 7.6 watts, about 2.8 kWh/yr (~$0.45/yr at $0.16/kWh) for 1 hr/day shower timers or 66.6 kWh/yr (~$10.66/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

Why does rigid 6 in. diameter ducting protect Broan-Nutone PTE511RK = PTE511H with PTE511RKF airflow?

Connecting Broan-Nutone PTE511RK = PTE511H with PTE511RKF through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Broan-Nutone PTE511RK = PTE511H with PTE511RKF performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone PTE511RK = PTE511H with PTE511RKF lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series PTE511RK = PTE511H with PTE511RKF / PREMIUM PD ID 4191418 (Qualified 2025-05-23)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Broan-Nutone PTE511RK = PTE511H with PTE511RKF?

Calculated coverage metrics translate Broan-Nutone PTE511RK = PTE511H with PTE511RKF airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Broan-Nutone PTE511RK = PTE511H with PTE511RKF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110.8 CFM
Tall Bath (9-ft Ceiling)Up to 98 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.8 kWh/yr (~$0.45/yr)7.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.266.6 kWh/yr (~$10.66/yr)7.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Broan-Nutone PTE511RK = PTE511H with PTE511RKF?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Broan PTE511RKY 110 / 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Panasonic FV-0511VKS3S 110 / 111.9 CFM Unpublished 15.1 CFM/W 6 in. diameter
Delta SIG80-110 110 / 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter

Does Broan-Nutone PTE511RK = PTE511H with PTE511RKF match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone PTE511RK = PTE511H with PTE511RKF percentage capacity without sending data.

Where should contractors skip Broan-Nutone PTE511RK = PTE511H with PTE51 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone PTE511RK = PTE511H with PTE51 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 60 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 110.8 CFM net static output
  • Works well for: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for Broan-Nutone PTE511RK = PTE511H with PTE511RKF?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone PTE511RK = PTE511H with PTE511RKF.

How much power does Broan-Nutone PTE511RK = PTE511H with PTE511RKF consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan-Nutone PTE511RK = PTE511H with PTE511RKF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan-Nutone PTE511RK = PTE511H with PTE511RKF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTE511RK = PTE511H with PTE511RKF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone PTE511RK = PTE511H with PTE511RKF?

Broan-Nutone PTE511RK = PTE511H with PTE511RKF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone PTE511RK = PTE511H with PTE511RKF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTE511RK = PTE511H with PTE511RKF's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan-Nutone PTE511RK = PTE511H with PTE511RKF score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTE511RK = PTE511H with PTE511RKF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan-Nutone PTE511RK = PTE511H with PTE511RKF?

Rule out Broan-Nutone PTE511RK = PTE511H with PTE511RKF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan-Nutone PTE511RK = PTE511H with PTE511RKF capacity?

Because static drag at 0.25 in. w.g. lowers Broan-Nutone PTE511RK = PTE511H with PTE511RKF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan-Nutone PTE511RK = PTE511H with PTE511RKF compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Broan-Nutone PTE511RK = PTE511H with PTE511RKF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories