Certified by EPA ENERGY STAR, Broan-Nutone PTE511RK = PTE511H with PTE511RKF delivers 110 CFM free-air (112 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 10.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 112 sq ft (8-ft height) or 99 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTE511RK = PTE511H with PTE511RKF Exhaust before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 112 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.5 CFM/W (#158/1,145)
- Static Retention
- 101.8% @ 0.25"
- Motor Draw
- 10.5 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Broan-Nutone PTE511RK = PTE511H with PTE511RKF vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PTE511RK = PTE511H with PTE511RKF (EPA filing PD #4191419) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112 CFM out of 110 CFM (101.8% retention, 14.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Broan-Nutone maintains 48 active ENERGY STAR blowers; PTE511RK = PTE511H with PTE511RKF (series: PREMIUM) (PD #4191419) gained qualification on 2025-05-23. Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
Why does rigid 4 in. diameter ducting protect Broan-Nutone PTE511RK = PTE511H with PTE511RKF airflow?
Connecting Broan-Nutone PTE511RK = PTE511H with PTE511RKF through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Broan-Nutone PTE511RK = PTE511H with PTE511RKF performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Broan-Nutone PTE511RK = PTE511H with PTE511RKF lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PTE511RK = PTE511H with PTE511RKF / PREMIUM | PD ID 4191419 (Qualified 2025-05-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Broan-Nutone PTE511RK = PTE511H with PTE511RKF?
Calculated coverage metrics translate Broan-Nutone PTE511RK = PTE511H with PTE511RKF airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Broan-Nutone PTE511RK = PTE511H with PTE511RKF?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
Does Broan-Nutone PTE511RK = PTE511H with PTE511RKF match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Broan-Nutone PTE511RK = PTE511H with PTE511RKF percentage capacity without sending data.
Where should contractors skip Broan-Nutone PTE511RK = PTE511H with PTE51 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan-Nutone PTE511RK = PTE511H with PTE51 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 62 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 112 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Broan-Nutone PTE511RK = PTE511H with PTE511RKF?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Broan-Nutone PTE511RK = PTE511H with PTE511RKF.
How much power does Broan-Nutone PTE511RK = PTE511H with PTE511RKF consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Broan-Nutone PTE511RK = PTE511H with PTE511RKF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Broan-Nutone PTE511RK = PTE511H with PTE511RKF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTE511RK = PTE511H with PTE511RKF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PTE511RK = PTE511H with PTE511RKF?
Broan-Nutone PTE511RK = PTE511H with PTE511RKF features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PTE511RK = PTE511H with PTE511RKF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTE511RK = PTE511H with PTE511RKF's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Broan-Nutone PTE511RK = PTE511H with PTE511RKF score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTE511RK = PTE511H with PTE511RKF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Broan-Nutone PTE511RK = PTE511H with PTE511RKF?
Rule out Broan-Nutone PTE511RK = PTE511H with PTE511RKF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Broan-Nutone PTE511RK = PTE511H with PTE511RKF capacity?
Because static drag at 0.25 in. w.g. lowers Broan-Nutone PTE511RK = PTE511H with PTE511RKF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Broan-Nutone PTE511RK = PTE511H with PTE511RKF compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Broan-Nutone PTE511RK = PTE511H with PTE511RKF produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)