Tested under HVI protocols, the Broan-Nutone PTE511RK exhaust unit achieves 110 CFM at 0.1 in. w.g. (112 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 10.5 CFM/W efficacy, covering standard baths up to 112 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone PTE511RK Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 112 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 10.5 CFM/W (#158/1,145)
- Static Retention
- 101.8% @ 0.25"
- Motor Draw
- 10.5 W (3.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Most Eff.

What does Broan-Nutone PTE511RK vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone PTE511RK (EPA filing PD #4191417) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112 CFM out of 110 CFM (101.8% retention, 14.1 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Broan-Nutone PTE511RK (series: PREMIUM) under PD #4191417 (48 models registered, 2025-05-23). Lighting kit: No. At 10.5 CFM/W (#158 of 1,145, top 14.8% of 1,145 rated models, more efficient than 85.2% of rated models, 5.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.5 watts, about 3.8 kWh/yr (~$0.61/yr at $0.16/kWh) for 1 hr/day shower timers or 92.0 kWh/yr (~$14.72/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
What attic duct routing preserves Broan-Nutone PTE511RK CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone PTE511RK, preventing premature peeling paint and mold growth.
How does Broan-Nutone PTE511RK measure up on airflow and noise ratings?
Each row below breaks down Broan-Nutone PTE511RK certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PTE511RK / PREMIUM | PD ID 4191417 (Qualified 2025-05-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan-Nutone PTE511RK CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112 CFM |
| Tall Bath (9-ft Ceiling) | Up to 99 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.8 kWh/yr (~$0.61/yr) | 10.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 92.0 kWh/yr (~$14.72/yr) | 10.5 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan-Nutone PTE511RK?
Compare Broan-Nutone PTE511RK side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
Can you size Broan-Nutone PTE511RK for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone PTE511RK verified capacity.
When does Broan-Nutone PTE511RK fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone PTE511RK.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 112 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 112 sq ft
- Target scenario: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Broan-Nutone PTE511RK?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone PTE511RK.
Will Broan-Nutone PTE511RK disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone PTE511RK at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan-Nutone PTE511RK continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone PTE511RK draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone PTE511RK pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone PTE511RK's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone PTE511RK?
Broan-Nutone PTE511RK features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone PTE511RK's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone PTE511RK's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone PTE511RK code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone PTE511RK clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone PTE511RK?
Do not force Broan-Nutone PTE511RK into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan-Nutone PTE511RK retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone PTE511RK produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)