BSH Home Appliances Corporation HCP30E51UC Exhaust Fan Specifications

ENERGY STAR PD #3417667 · Range Hood · Qualified 2024-03-01
Verified Specification Summary

Tested under HVI protocols, the BSH Home Appliances Corporation HCP30E51UC exhaust unit achieves 122.3 CFM at 0.1 in. w.g. (256.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 3.7 CFM/W efficacy, covering standard baths up to 256 sq ft on a 8 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside BSH Home Appliances Corporation HCP30E51UC Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
122.3 / 256.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
209.6% @ 0.25"
Motor Draw
33.1 W (12.1 kWh/yr)
Duct & Tier
8 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does BSH Home Appliances Corporation HCP30E51UC vs. 1,145-Model ENERGY STAR Benchmarks show?

BSH Home Appliances Corporation HCP30E51UC (EPA filing PD #3417667) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 256.3 CFM out of 122.3 CFM (209.6% retention, 121.9 pts higher retention than the 87.7% median). Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: BSH Home Appliances Corporation registers 1 certified model, with SKU HCP30E51UC (series: HCP30E51UC) (PD #3417667) certified since 2024-03-01. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.1 watts, about 12.1 kWh/yr (~$1.94/yr at $0.16/kWh) for 1 hr/day shower timers or 290.0 kWh/yr (~$46.40/yr) continuously. Closest competing matches include Greenheck SP-B110ES (118.0 CFM) and KORA SBF110N (119.2 CFM).

What attic duct routing preserves BSH Home Appliances Corporation HCP30E51UC CFM output?

Short straight 8 in. diameter duct paths retain up to ~82% of open-air capacity on BSH Home Appliances Corporation HCP30E51UC, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does BSH Home Appliances Corporation HCP30E51UC measure up on airflow and noise ratings?

Each row below breaks down BSH Home Appliances Corporation HCP30E51UC certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share BSH Home Appliances Corporation (1 model) ENERGY STAR Certified Partner
Model Number & Series HCP30E51UC / HCP30E51UC PD ID 3417667 (Qualified 2024-03-01)
Duct Connection 8 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (256.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect BSH Home Appliances Corporation HCP30E51UC CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for BSH Home Appliances Corporation HCP30E51UC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 256 sq ft1 CFM/sq ft @ 256.3 CFM
Tall Bath (9-ft Ceiling)Up to 227 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 206 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.1 kWh/yr (~$1.94/yr)33.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2290.0 kWh/yr (~$46.40/yr)33.1 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against BSH Home Appliances Corporation HCP30E51UC?

Compare BSH Home Appliances Corporation HCP30E51UC side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Greenheck SP-B110ES 118 / 100 CFM 1.5 sones 4.0 CFM/W 6 in. diameter
KORA SBF110N 119.2 / N/A CFM 1.6 sones 3.5 CFM/W 4 in. diameter
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Nutone QTN130LE1 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan QT130E 130 / 130.4 CFM 1.5 sones 4.7 CFM/W 6 in. diameter

Can you size BSH Home Appliances Corporation HCP30E51UC for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against BSH Home Appliances Corporation HCP30E51UC verified capacity.

Where should contractors skip BSH Home Appliances Corporation HCP30E51UC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for BSH Home Appliances Corporation HCP30E51UC carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 256.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around ENERGY STAR sones up to 256 sq ft
  • Works well for: Paired with rigid galvanized 8 in. diameter transition

How do federal and code standards apply to BSH Home Appliances Corporation HCP30E51UC?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for BSH Home Appliances Corporation HCP30E51UC.

Will long attic ducting choke BSH Home Appliances Corporation HCP30E51UC capacity?

Because static drag at 0.25 in. w.g. lowers BSH Home Appliances Corporation HCP30E51UC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is BSH Home Appliances Corporation HCP30E51UC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, BSH Home Appliances Corporation HCP30E51UC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does BSH Home Appliances Corporation HCP30E51UC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, BSH Home Appliances Corporation HCP30E51UC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can BSH Home Appliances Corporation HCP30E51UC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from BSH Home Appliances Corporation HCP30E51UC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing BSH Home Appliances Corporation HCP30E51UC?

BSH Home Appliances Corporation HCP30E51UC features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change BSH Home Appliances Corporation HCP30E51UC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing BSH Home Appliances Corporation HCP30E51UC's safe coverage footprint from 50 sq ft to 44 sq ft.

How does BSH Home Appliances Corporation HCP30E51UC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), BSH Home Appliances Corporation HCP30E51UC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify BSH Home Appliances Corporation HCP30E51UC?

Rule out BSH Home Appliances Corporation HCP30E51UC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories