Skip to main content
Grant Estimator

Air King ESZ303ADA Exhaust Fan Specifications

ENERGY STAR PD #2369807 · Range Hood · Qualified 2020-11-20
Verified Specification Summary

Certified by EPA ENERGY STAR, Air King ESZ303ADA delivers 120 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 7.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 120 sq ft (8-ft height) or 106 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESZ303ADA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.9 CFM/W (#356/1,145)
Static Retention
0.1" test only
Motor Draw
15.2 W (5.5 kWh/yr)
Duct & Tier
3.25 x 1 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King ESZ303ADA vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King ESZ303ADA (EPA filing PD #2369807) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.

Air King maintains 62 active ENERGY STAR blowers; ESZ303ADA (series: Air King) (PD #2369807) gained qualification on 2020-11-20. Lighting kit: Yes. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

Why does rigid 3.25 x 1 in. rectangular ducting protect Air King ESZ303ADA airflow?

Connecting Air King ESZ303ADA through rigid 3.25 x 1 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King ESZ303ADA performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King ESZ303ADA lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series ESZ303ADA / Air King PD ID 2369807 (Qualified 2020-11-20)
Duct Connection 3.25 x 1 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Air King ESZ303ADA?

Calculated coverage metrics translate Air King ESZ303ADA airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King ESZ303ADA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.5 kWh/yr (~$0.88/yr)15.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2133.2 kWh/yr (~$21.31/yr)15.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King ESZ303ADA?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Air King ESZ303ADA match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King ESZ303ADA percentage capacity without sending data.

Does Air King ESZ303ADA suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King ESZ303ADA for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 70 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 120 CFM net static output
  • Best application: Collar pairs with 3.25 x 1 in. rectangular duct straight outdoors

Which homeowner questions come up most for Air King ESZ303ADA?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King ESZ303ADA.

What acoustic sone tier does Air King ESZ303ADA occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Air King ESZ303ADA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Air King ESZ303ADA add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Air King ESZ303ADA averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Air King ESZ303ADA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESZ303ADA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King ESZ303ADA?

Air King ESZ303ADA features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King ESZ303ADA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESZ303ADA's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Air King ESZ303ADA pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King ESZ303ADA easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Air King ESZ303ADA in a bathroom remodel?

Avoid specifying Air King ESZ303ADA in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Air King ESZ303ADA airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King ESZ303ADA achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3.25 x 1 in. rectangular smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories