Rated for 120 CFM open-air (unpublished 0.25 in. w.g. output), Air King ESZ363ADA omits a published 0.1-inch sone rating and delivers 7.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 120 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESZ363ADA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.9 CFM/W (#356/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 15.2 W (5.5 kWh/yr)
- Duct & Tier
- 3.25 x 1 in. rectangular · Standard

What does Air King ESZ363ADA vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King ESZ363ADA (EPA filing PD #2369808) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.
Brand catalog footprint: Air King registers 62 certified models, with SKU ESZ363ADA (series: Air King) (PD #2369808) certified since 2020-11-20. Lighting kit: Yes. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
How do flex elbows choke Air King ESZ363ADA at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3.25 x 1 in. rectangular metal pipe keeps Air King ESZ363ADA moving full rated CFM.
Does Air King ESZ363ADA meet residential exhaust fan code specs?
Inspect Air King ESZ363ADA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ESZ363ADA / Air King | PD ID 2369808 (Qualified 2020-11-20) |
| Duct Connection | 3.25 x 1 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Which bathroom duties match Air King ESZ363ADA airflow output?
Annual electricity figures and room square-footage ceilings below reflect Air King ESZ363ADA tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 133.2 kWh/yr (~$21.31/yr) | 15.2 W x 8,760 hrs / 1,000 |
Which competing models share Air King ESZ363ADA airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
How much airflow margin does Air King ESZ363ADA give your bath?
Run a quick local room-volume check for Air King ESZ363ADA by entering square footage and ceiling height to spot under-vented steam risks early.
Which bath layouts should avoid specifying Air King ESZ363ADA?
Match Air King ESZ363ADA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 3.25 x 1 in. rectangular
What should homeowners verify first about Air King ESZ363ADA?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King ESZ363ADA.
Where does Air King ESZ363ADA run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King ESZ363ADA.
What happens to Air King ESZ363ADA CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Air King ESZ363ADA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3.25 x 1 in. rectangular collar.
Where does Air King ESZ363ADA sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Air King ESZ363ADA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Air King ESZ363ADA cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Air King ESZ363ADA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Air King ESZ363ADA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESZ363ADA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King ESZ363ADA?
Air King ESZ363ADA features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King ESZ363ADA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESZ363ADA's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Air King ESZ363ADA ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King ESZ363ADA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)