Skip to main content
Grant Estimator

Air King ESZ363ADA Exhaust Fan Specifications

ENERGY STAR PD #2369808 · Range Hood · Qualified 2020-11-20
Verified Specification Summary

Rated for 120 CFM open-air (unpublished 0.25 in. w.g. output), Air King ESZ363ADA omits a published 0.1-inch sone rating and delivers 7.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 120 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESZ363ADA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
120 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
7.9 CFM/W (#356/1,145)
Static Retention
0.1" test only
Motor Draw
15.2 W (5.5 kWh/yr)
Duct & Tier
3.25 x 1 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King ESZ363ADA vs. 1,145-Model ENERGY STAR Benchmarks show?

Air King ESZ363ADA (EPA filing PD #2369808) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.

Brand catalog footprint: Air King registers 62 certified models, with SKU ESZ363ADA (series: Air King) (PD #2369808) certified since 2020-11-20. Lighting kit: Yes. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).

How do flex elbows choke Air King ESZ363ADA at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3.25 x 1 in. rectangular metal pipe keeps Air King ESZ363ADA moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Air King ESZ363ADA meet residential exhaust fan code specs?

Inspect Air King ESZ363ADA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series ESZ363ADA / Air King PD ID 2369808 (Qualified 2020-11-20)
Duct Connection 3.25 x 1 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (120 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Air King ESZ363ADA airflow output?

Annual electricity figures and room square-footage ceilings below reflect Air King ESZ363ADA tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Air King ESZ363ADA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 120 sq ft1 CFM/sq ft @ 120 CFM
Tall Bath (9-ft Ceiling)Up to 106 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 70 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.5 kWh/yr (~$0.88/yr)15.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2133.2 kWh/yr (~$21.31/yr)15.2 W x 8,760 hrs / 1,000

Which competing models share Air King ESZ363ADA airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-N110LHA 110 / 92.1 CFM 1.5 sones 6.1 CFM/W 3 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Air King ESZ363ADA give your bath?

Run a quick local room-volume check for Air King ESZ363ADA by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Air King ESZ363ADA?

Match Air King ESZ363ADA directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 3.25 x 1 in. rectangular

What should homeowners verify first about Air King ESZ363ADA?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Air King ESZ363ADA.

Where does Air King ESZ363ADA run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Air King ESZ363ADA.

What happens to Air King ESZ363ADA CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Air King ESZ363ADA moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3.25 x 1 in. rectangular collar.

Where does Air King ESZ363ADA sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Air King ESZ363ADA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Air King ESZ363ADA cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Air King ESZ363ADA 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Air King ESZ363ADA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESZ363ADA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King ESZ363ADA?

Air King ESZ363ADA features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King ESZ363ADA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESZ363ADA's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Air King ESZ363ADA ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Air King ESZ363ADA covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories