The Air King ESZ368ADA (Air King) moves 120 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 7.9 CFM/W efficacy, sizing bathrooms up to 120 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King ESZ368ADA Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 120 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 7.9 CFM/W (#356/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 15.2 W (5.5 kWh/yr)
- Duct & Tier
- 3.25 x 1 in. rectangular · Standard

What does Air King ESZ368ADA vs. 1,145-Model ENERGY STAR Benchmarks show?
Air King ESZ368ADA (EPA filing PD #2369810) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.
Free-discharge delivery reaches 120 CFM (#289 of 1,145 certified models) via a 3.25 x 1 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 1 in. rectangular housing before entering attic bays.
Brand catalog footprint: Air King registers 62 certified models, with SKU ESZ368ADA (series: Air King) (PD #2369810) certified since 2020-11-20. Lighting kit: Yes. At 7.9 CFM/W (#356 of 1,145, top 31.8% of 1,145 rated models, more efficient than 68.2% of rated models, 3.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.2 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 133.2 kWh/yr (~$21.31/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech UTLDR110 (110.0 CFM).
How does duct geometry alter Air King ESZ368ADA static pressure?
Smooth 3.25 x 1 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Air King ESZ368ADA?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Air King ESZ368ADA alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ESZ368ADA / Air King | PD ID 2369810 (Qualified 2020-11-20) |
| Duct Connection | 3.25 x 1 in. rectangular | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (120 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Air King ESZ368ADA ventilate safely?
Sizing outputs below convert Air King ESZ368ADA tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 120 sq ft | 1 CFM/sq ft @ 120 CFM |
| Tall Bath (9-ft Ceiling) | Up to 106 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 70 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 5.5 kWh/yr (~$0.88/yr) | 15.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 133.2 kWh/yr (~$21.31/yr) | 15.2 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Air King ESZ368ADA closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Panasonic Eco Solutions RG-N110LHA | 110 / 92.1 CFM | 1.5 sones | 6.1 CFM/W | 3 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will Air King ESZ368ADA clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Air King ESZ368ADA satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Air King ESZ368ADA in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Air King ESZ368ADA for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 70 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 120 sq ft with 8-ft ceilings (106 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 3.25 x 1 in. rectangular
What key rules and numbers govern Air King ESZ368ADA?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Air King ESZ368ADA.
What electrical efficiency and runtime kWh define Air King ESZ368ADA?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Air King ESZ368ADA pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King ESZ368ADA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King ESZ368ADA?
Air King ESZ368ADA features a 3.25 x 1 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King ESZ368ADA's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King ESZ368ADA's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King ESZ368ADA satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Air King ESZ368ADA clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Air King ESZ368ADA undersized or poorly matched for a bath renovation?
Skip Air King ESZ368ADA if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Air King ESZ368ADA CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Air King ESZ368ADA registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3.25 x 1 in. rectangular duct runs vital.
How does Air King ESZ368ADA sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Air King ESZ368ADA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)