The Delta ELT80-110HLED (BreezElite) moves 100 CFM at 0.1 in. w.g. (84.1 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.2 CFM/W efficacy, sizing bathrooms up to 84 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110HLED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 84.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.2 CFM/W (#282/1,145)
- Static Retention
- 84.1% @ 0.25"
- Motor Draw
- 10.9 W (4.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta ELT80-110HLED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta ELT80-110HLED (EPA filing PD #2343282) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Delta ELT80-110HLED (series: BreezElite) under PD #2343282 (121 models registered, 2018-12-21). Lighting kit: Yes. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.9 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 95.5 kWh/yr (~$15.28/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).
How does duct geometry alter Delta ELT80-110HLED static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Delta ELT80-110HLED?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta ELT80-110HLED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ELT80-110HLED / BreezElite | PD ID 2343282 (Qualified 2018-12-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Delta ELT80-110HLED ventilate safely?
Sizing outputs below convert Delta ELT80-110HLED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 10.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 95.5 kWh/yr (~$15.28/yr) | 10.9 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Delta ELT80-110HLED closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-MB | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-03 | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will Delta ELT80-110HLED clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Delta ELT80-110HLED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Where should contractors skip Delta ELT80-110HLED on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Delta ELT80-110HLED carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Steam or walk-in tub room > 34 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Choose this if: Bathroom floor <= 84 sq ft with 8-ft ceilings (74 sq ft at 9-ft height)
- Works well for: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Delta ELT80-110HLED?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta ELT80-110HLED.
How loud is Delta ELT80-110HLED compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, Delta ELT80-110HLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Delta ELT80-110HLED consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Delta ELT80-110HLED draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Delta ELT80-110HLED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110HLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ELT80-110HLED?
Delta ELT80-110HLED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ELT80-110HLED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110HLED's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Delta ELT80-110HLED score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Delta ELT80-110HLED delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Delta ELT80-110HLED?
Rule out Delta ELT80-110HLED when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke Delta ELT80-110HLED capacity?
Because static drag at 0.25 in. w.g. lowers Delta ELT80-110HLED from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)