In EPA dataset 8dv7-nngq, Delta ELT80-110LED tests at 100 CFM free discharge (84.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 84 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 84.1 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.2 CFM/W (#282/1,145)
- Static Retention
- 84.1% @ 0.25"
- Motor Draw
- 10.9 W (4.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta ELT80-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta ELT80-110LED (EPA filing PD #2343278) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Delta ELT80-110LED (series: BreezElite) under PD #2343278 (121 models registered, 2018-12-21). Lighting kit: Yes. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.9 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 95.5 kWh/yr (~$15.28/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).
Why avoid unvented attic termination with Delta ELT80-110LED?
Under ASHRAE 62.2 best practice, Delta ELT80-110LED needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta ELT80-110LED?
Before cutting ceiling drywall or sizing attic transitions for Delta ELT80-110LED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ELT80-110LED / BreezElite | PD ID 2343278 (Qualified 2018-12-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (84.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta ELT80-110LED?
Bathroom ventilation sizing below maps Delta ELT80-110LED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 84 sq ft | 1 CFM/sq ft @ 84.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 74 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 34 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 10.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 95.5 kWh/yr (~$15.28/yr) | 10.9 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta ELT80-110LED in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta ELT80-110LED.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-MB | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-03 | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
What percentage of room demand does Delta ELT80-110LED cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta ELT80-110LED tested delivery.
What plumbing or duct constraints rule out Delta ELT80-110LED?
Compare where Delta ELT80-110LED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 84.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 84 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Delta ELT80-110LED?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta ELT80-110LED.
Is Delta ELT80-110LED energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta ELT80-110LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ELT80-110LED?
Delta ELT80-110LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ELT80-110LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta ELT80-110LED serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110LED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Delta ELT80-110LED for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110LED lacks adequate reserve.
How does Delta ELT80-110LED handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110LED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Delta ELT80-110LED quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Delta ELT80-110LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)