Skip to main content
Grant Estimator

Delta ELT80-110LED Exhaust Fan Specifications

ENERGY STAR PD #2343278 · Bathroom/Utility Room · Qualified 2018-12-21
Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta ELT80-110LED tests at 100 CFM free discharge (84.1 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 9.2 CFM/W efficacy, meeting residential IRC M1505 sizing up to 84 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110LED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
100 / 84.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.2 CFM/W (#282/1,145)
Static Retention
84.1% @ 0.25"
Motor Draw
10.9 W (4.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ELT80-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110LED (EPA filing PD #2343278) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 100 CFM open-air to 84.1 CFM at 0.25 in. w.g. (84.1% retention, 3.6 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta ELT80-110LED (series: BreezElite) under PD #2343278 (121 models registered, 2018-12-21). Lighting kit: Yes. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.9 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 95.5 kWh/yr (~$15.28/yr) continuously. Closest competing matches include Utilitech 7115-02 (100.0 CFM) and Utilitech 7115-02-BN (100.0 CFM).

Why avoid unvented attic termination with Delta ELT80-110LED?

Under ASHRAE 62.2 best practice, Delta ELT80-110LED needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Delta ELT80-110LED?

Before cutting ceiling drywall or sizing attic transitions for Delta ELT80-110LED, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ELT80-110LED / BreezElite PD ID 2343278 (Qualified 2018-12-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (84.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Delta ELT80-110LED?

Bathroom ventilation sizing below maps Delta ELT80-110LED motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110LED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 84 sq ft1 CFM/sq ft @ 84.1 CFM
Tall Bath (9-ft Ceiling)Up to 74 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 34 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.0 kWh/yr (~$0.64/yr)10.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.295.5 kWh/yr (~$15.28/yr)10.9 W x 8,760 hrs / 1,000

What peer models sit nearest Delta ELT80-110LED in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta ELT80-110LED.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-03 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

What percentage of room demand does Delta ELT80-110LED cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta ELT80-110LED tested delivery.

What plumbing or duct constraints rule out Delta ELT80-110LED?

Compare where Delta ELT80-110LED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 84.1 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 84 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Delta ELT80-110LED?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta ELT80-110LED.

Is Delta ELT80-110LED energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta ELT80-110LED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ELT80-110LED?

Delta ELT80-110LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ELT80-110LED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta ELT80-110LED serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110LED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Delta ELT80-110LED for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110LED lacks adequate reserve.

How does Delta ELT80-110LED handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110LED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Delta ELT80-110LED quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta ELT80-110LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories