Delta ELT80-110HLED Exhaust Fan Specifications

ENERGY STAR PD #2343281 · Bathroom/Utility Room · Qualified 2018-12-21
Verified Specification Summary

The Delta ELT80-110HLED (BreezElite) moves 110 CFM at 0.1 in. w.g. (92.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 11.9 CFM/W efficacy, sizing bathrooms up to 92 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110HLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 92.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.9 CFM/W (#85/1,145)
Static Retention
83.9% @ 0.25"
Motor Draw
9.2 W (3.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ELT80-110HLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110HLED (EPA filing PD #2343281) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.3 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Delta ELT80-110HLED (series: BreezElite) under PD #2343281 (121 models registered, 2018-12-21). Lighting kit: Yes. At 11.9 CFM/W (#85 of 1,145, top 7.8% of 1,145 rated models, more efficient than 92.2% of rated models, 7.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How does duct geometry alter Delta ELT80-110HLED static pressure?

Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Delta ELT80-110HLED?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta ELT80-110HLED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ELT80-110HLED / BreezElite PD ID 2343281 (Qualified 2018-12-21)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (92.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Delta ELT80-110HLED ventilate safely?

Sizing outputs below convert Delta ELT80-110HLED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110HLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 92 sq ft1 CFM/sq ft @ 92.3 CFM
Tall Bath (9-ft Ceiling)Up to 82 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 42 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.280.6 kWh/yr (~$12.90/yr)9.2 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Delta ELT80-110HLED closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter

Will Delta ELT80-110HLED clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Delta ELT80-110HLED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Delta ELT80-110HLED fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Delta ELT80-110HLED.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 42 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 92 sq ft with 8-ft ceilings (82 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 6 in. diameter

What key rules and numbers govern Delta ELT80-110HLED?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta ELT80-110HLED.

Will Delta ELT80-110HLED disturb adjacent bedrooms during night use?

Acoustic measurement places Delta ELT80-110HLED at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Delta ELT80-110HLED continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Delta ELT80-110HLED draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Delta ELT80-110HLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110HLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ELT80-110HLED?

Delta ELT80-110HLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ELT80-110HLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110HLED's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Delta ELT80-110HLED code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Delta ELT80-110HLED clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Delta ELT80-110HLED?

Do not force Delta ELT80-110HLED into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Delta ELT80-110HLED retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Delta ELT80-110HLED produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 in. diameter metal duct transitions.