Skip to main content
Grant Estimator

Delta ELT80-110MH Exhaust Fan Specifications

ENERGY STAR PD #2343270 · Bathroom/Utility Room · Qualified 2018-12-21
Verified Specification Summary

Rated for 110 CFM open-air (93.7 CFM at 0.25 in. w.g.), Delta ELT80-110MH omits a published 0.1-inch sone rating and delivers 9.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 93 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110MH Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 93.7 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
9.2 CFM/W (#282/1,145)
Static Retention
85.2% @ 0.25"
Motor Draw
12.0 W (4.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ELT80-110MH vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110MH (EPA filing PD #2343270) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 93.7 CFM out of 110 CFM (85.2% retention, 2.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Delta ELT80-110MH (series: BreezElite) under PD #2343270 (121 models registered, 2018-12-21). Lighting kit: No. At 9.2 CFM/W (#282 of 1,145, top 25.4% of 1,145 rated models, more efficient than 74.6% of rated models, 4.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.0 watts, about 4.4 kWh/yr (~$0.70/yr at $0.16/kWh) for 1 hr/day shower timers or 105.1 kWh/yr (~$16.82/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).

How do flex elbows choke Delta ELT80-110MH at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Delta ELT80-110MH moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Delta ELT80-110MH meet residential exhaust fan code specs?

Inspect Delta ELT80-110MH mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ELT80-110MH / BreezElite PD ID 2343270 (Qualified 2018-12-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (93.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Delta ELT80-110MH airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta ELT80-110MH tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110MH
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 93 sq ft1 CFM/sq ft @ 93.7 CFM
Tall Bath (9-ft Ceiling)Up to 83 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 43 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.4 kWh/yr (~$0.70/yr)12.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2105.1 kWh/yr (~$16.82/yr)12.0 W x 8,760 hrs / 1,000

Which competing models share Delta ELT80-110MH airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does Delta ELT80-110MH give your bath?

Run a quick local room-volume check for Delta ELT80-110MH by entering square footage and ceiling height to spot under-vented steam risks early.

Who should not install Delta ELT80-110MH in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta ELT80-110MH for residential use.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 43 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Ideal fit: Bathroom floor <= 93 sq ft with 8-ft ceilings (83 sq ft at 9-ft height)
  • Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Delta ELT80-110MH?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta ELT80-110MH.

What electrical efficiency and runtime kWh define Delta ELT80-110MH?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Delta ELT80-110MH pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110MH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ELT80-110MH?

Delta ELT80-110MH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ELT80-110MH's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110MH's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Delta ELT80-110MH satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta ELT80-110MH clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Delta ELT80-110MH undersized or poorly matched for a bath renovation?

Skip Delta ELT80-110MH if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Delta ELT80-110MH CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta ELT80-110MH registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Delta ELT80-110MH sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Delta ELT80-110MH produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories