Tested under HVI protocols, the Delta ELT80-110MHLED exhaust unit achieves 110 CFM at 0.1 in. w.g. (92.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.9 CFM/W efficacy, covering standard baths up to 92 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110MHLED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 92.3 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 11.9 CFM/W (#85/1,145)
- Static Retention
- 83.9% @ 0.25"
- Motor Draw
- 9.2 W (3.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Delta ELT80-110MHLED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta ELT80-110MHLED (EPA filing PD #2343283) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.3 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Delta maintains 121 active ENERGY STAR blowers; ELT80-110MHLED (series: BreezElite) (PD #2343283) gained qualification on 2018-12-21. Lighting kit: Yes. At 11.9 CFM/W (#85 of 1,145, top 7.8% of 1,145 rated models, more efficient than 92.2% of rated models, 7.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
What attic duct routing preserves Delta ELT80-110MHLED CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta ELT80-110MHLED, preventing premature peeling paint and mold growth.
How does Delta ELT80-110MHLED measure up on airflow and noise ratings?
Each row below breaks down Delta ELT80-110MHLED certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ELT80-110MHLED / BreezElite | PD ID 2343283 (Qualified 2018-12-21) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (92.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Delta ELT80-110MHLED CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 92 sq ft | 1 CFM/sq ft @ 92.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 82 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 42 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.4 kWh/yr (~$0.54/yr) | 9.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 80.6 kWh/yr (~$12.90/yr) | 9.2 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta ELT80-110MHLED?
Compare Delta ELT80-110MHLED side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
Can you size Delta ELT80-110MHLED for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta ELT80-110MHLED verified capacity.
What plumbing or duct constraints rule out Delta ELT80-110MHLED?
Compare where Delta ELT80-110MHLED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 92.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around ENERGY STAR sones up to 92 sq ft
- Suited to: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Delta ELT80-110MHLED?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta ELT80-110MHLED.
Why might a contractor swap Delta ELT80-110MHLED for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110MHLED lacks adequate reserve.
How does Delta ELT80-110MHLED handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110MHLED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Delta ELT80-110MHLED quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Delta ELT80-110MHLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Delta ELT80-110MHLED energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Delta ELT80-110MHLED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110MHLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta ELT80-110MHLED?
Delta ELT80-110MHLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta ELT80-110MHLED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110MHLED's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Delta ELT80-110MHLED serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110MHLED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)