Delta ELT80-110MHLED Exhaust Fan Specifications

ENERGY STAR PD #2343283 · Bathroom/Utility Room · Qualified 2018-12-21
Verified Specification Summary

Tested under HVI protocols, the Delta ELT80-110MHLED exhaust unit achieves 110 CFM at 0.1 in. w.g. (92.3 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 11.9 CFM/W efficacy, covering standard baths up to 92 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta ELT80-110MHLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 92.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
11.9 CFM/W (#85/1,145)
Static Retention
83.9% @ 0.25"
Motor Draw
9.2 W (3.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta ELT80-110MHLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta ELT80-110MHLED (EPA filing PD #2343283) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 110 CFM open-air to 92.3 CFM at 0.25 in. w.g. (83.9% retention, 3.8 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Delta maintains 121 active ENERGY STAR blowers; ELT80-110MHLED (series: BreezElite) (PD #2343283) gained qualification on 2018-12-21. Lighting kit: Yes. At 11.9 CFM/W (#85 of 1,145, top 7.8% of 1,145 rated models, more efficient than 92.2% of rated models, 7.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.2 watts, about 3.4 kWh/yr (~$0.54/yr at $0.16/kWh) for 1 hr/day shower timers or 80.6 kWh/yr (~$12.90/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

What attic duct routing preserves Delta ELT80-110MHLED CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta ELT80-110MHLED, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Delta ELT80-110MHLED measure up on airflow and noise ratings?

Each row below breaks down Delta ELT80-110MHLED certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series ELT80-110MHLED / BreezElite PD ID 2343283 (Qualified 2018-12-21)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (92.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Delta ELT80-110MHLED CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Delta ELT80-110MHLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 92 sq ft1 CFM/sq ft @ 92.3 CFM
Tall Bath (9-ft Ceiling)Up to 82 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 42 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.4 kWh/yr (~$0.54/yr)9.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.280.6 kWh/yr (~$12.90/yr)9.2 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Delta ELT80-110MHLED?

Compare Delta ELT80-110MHLED side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter

Can you size Delta ELT80-110MHLED for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta ELT80-110MHLED verified capacity.

What plumbing or duct constraints rule out Delta ELT80-110MHLED?

Compare where Delta ELT80-110MHLED excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 92.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around ENERGY STAR sones up to 92 sq ft
  • Suited to: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to Delta ELT80-110MHLED?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta ELT80-110MHLED.

Why might a contractor swap Delta ELT80-110MHLED for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Delta ELT80-110MHLED lacks adequate reserve.

How does Delta ELT80-110MHLED handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Delta ELT80-110MHLED yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Delta ELT80-110MHLED quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Delta ELT80-110MHLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Delta ELT80-110MHLED energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Delta ELT80-110MHLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta ELT80-110MHLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta ELT80-110MHLED?

Delta ELT80-110MHLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta ELT80-110MHLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta ELT80-110MHLED's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Delta ELT80-110MHLED serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Delta ELT80-110MHLED supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories