Tested under HVI protocols, the Delta SIG80-110DLED exhaust unit achieves 110 CFM at 0.1 in. w.g. (112.9 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 12.8 CFM/W efficacy, covering standard baths up to 112 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110DLED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 112.9 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 12.8 CFM/W (#60/1,145)
- Static Retention
- 102.6% @ 0.25"
- Motor Draw
- 8.6 W (3.1 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Delta SIG80-110DLED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SIG80-110DLED (EPA filing PD #2343187) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
EPA filing PD #2343187 verifies SIG80-110DLED (series: BreezSignature) under Delta (121 listed models, qualified 2018-01-19). Lighting kit: Yes. At 12.8 CFM/W (#60 of 1,145, top 5.5% of 1,145 rated models, more efficient than 94.5% of rated models, 8.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).
What attic duct routing preserves Delta SIG80-110DLED CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Delta SIG80-110DLED, preventing premature peeling paint and mold growth.
How does Delta SIG80-110DLED measure up on airflow and noise ratings?
Each row below breaks down Delta SIG80-110DLED certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SIG80-110DLED / BreezSignature | PD ID 2343187 (Qualified 2018-01-19) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (112.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect Delta SIG80-110DLED CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 112 sq ft | 1 CFM/sq ft @ 112.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 100 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 62 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 3.1 kWh/yr (~$0.50/yr) | 8.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 75.3 kWh/yr (~$12.05/yr) | 8.6 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Delta SIG80-110DLED?
Compare Delta SIG80-110DLED side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Revent RVL110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| Revent RVLH110 | 110 / 120.2 CFM | 1.2 sones | 11.3 CFM/W | 4 in. diameter |
| DewStop - Breeze Easy BEL110 | 110 / 113.6 CFM | 1.2 sones | 11.2 CFM/W | 4 in. diameter |
| Loren Cook Company GCVF 100 | 127 / N/A CFM | 1.7 sones | 11.1 CFM/W | 5.94 in. diameter |
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
Can you size Delta SIG80-110DLED for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Delta SIG80-110DLED verified capacity.
Which bath layouts should avoid specifying Delta SIG80-110DLED?
Match Delta SIG80-110DLED directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 112.9 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around ENERGY STAR sones up to 112 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Delta SIG80-110DLED?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Delta SIG80-110DLED.
What does Delta SIG80-110DLED cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Delta SIG80-110DLED 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Delta SIG80-110DLED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110DLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SIG80-110DLED?
Delta SIG80-110DLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SIG80-110DLED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110DLED's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Delta SIG80-110DLED ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110DLED covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Delta SIG80-110DLED run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta SIG80-110DLED.
What happens to Delta SIG80-110DLED CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Delta SIG80-110DLED moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Delta SIG80-110DLED sit on acoustic comfort for senior homeowners?
Measuring an unpublished 0.1-in sone rating, Delta SIG80-110DLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)