Skip to main content
Grant Estimator

Delta SIG80-110ELED Exhaust Fan Specifications

ENERGY STAR PD #2343179 · Bathroom/Utility Room · Qualified 2018-09-28
Verified Specification Summary

Certified by EPA ENERGY STAR, Delta SIG80-110ELED delivers 110 CFM free-air (100.3 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 8.2 CFM/W efficacy, clearing residential IRC M1505 sizing up to 100 sq ft (8-ft height) or 89 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110ELED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 100.3 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.2 CFM/W (#330/1,145)
Static Retention
91.2% @ 0.25"
Motor Draw
13.4 W (4.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SIG80-110ELED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110ELED (EPA filing PD #2343179) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 100.3 CFM out of 110 CFM (91.2% retention, 3.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Delta registers 121 certified models, with SKU SIG80-110ELED (series: BreezSignature) (PD #2343179) certified since 2018-09-28. Lighting kit: Yes. At 8.2 CFM/W (#330 of 1,145, top 29.4% of 1,145 rated models, more efficient than 70.6% of rated models, 3.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.4 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 117.4 kWh/yr (~$18.78/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Utilitech 7115-02 (100.0 CFM).

Why does rigid 4 in. diameter ducting protect Delta SIG80-110ELED airflow?

Connecting Delta SIG80-110ELED through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Delta SIG80-110ELED performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Delta SIG80-110ELED lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SIG80-110ELED / BreezSignature PD ID 2343179 (Qualified 2018-09-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (100.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Delta SIG80-110ELED?

Calculated coverage metrics translate Delta SIG80-110ELED airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110ELED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 100 sq ft1 CFM/sq ft @ 100.3 CFM
Tall Bath (9-ft Ceiling)Up to 89 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 50 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.9 kWh/yr (~$0.78/yr)13.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2117.4 kWh/yr (~$18.78/yr)13.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Delta SIG80-110ELED?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-CH 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-MB 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Does Delta SIG80-110ELED match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Delta SIG80-110ELED percentage capacity without sending data.

Does Delta SIG80-110ELED suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta SIG80-110ELED for your remodel.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 50 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Moisture load fits 100.3 CFM net static output
  • Best application: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Delta SIG80-110ELED?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Delta SIG80-110ELED.

Does Delta SIG80-110ELED pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110ELED easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta SIG80-110ELED in a bathroom remodel?

Avoid specifying Delta SIG80-110ELED in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Delta SIG80-110ELED airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta SIG80-110ELED achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Delta SIG80-110ELED occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Delta SIG80-110ELED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Delta SIG80-110ELED add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta SIG80-110ELED averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta SIG80-110ELED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110ELED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SIG80-110ELED?

Delta SIG80-110ELED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SIG80-110ELED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110ELED's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories