Delta SIG80-110HLED Exhaust Fan Specifications

ENERGY STAR PD #2343185 · Bathroom/Utility Room · Qualified 2018-01-19
Verified Specification Summary

Rated for 110 CFM open-air (112.9 CFM at 0.25 in. w.g.), Delta SIG80-110HLED omits a published 0.1-inch sone rating and delivers 12.8 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 112 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110HLED Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / 112.9 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
12.8 CFM/W (#60/1,145)
Static Retention
102.6% @ 0.25"
Motor Draw
8.6 W (3.1 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta SIG80-110HLED vs. 1,145-Model ENERGY STAR Benchmarks show?

Delta SIG80-110HLED (EPA filing PD #2343185) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 112.9 CFM out of 110 CFM (102.6% retention, 14.9 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Delta maintains 121 active ENERGY STAR blowers; SIG80-110HLED (series: BreezSignature) (PD #2343185) gained qualification on 2018-01-19. Lighting kit: Yes. At 12.8 CFM/W (#60 of 1,145, top 5.5% of 1,145 rated models, more efficient than 94.5% of rated models, 8.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 8.6 watts, about 3.1 kWh/yr (~$0.50/yr at $0.16/kWh) for 1 hr/day shower timers or 75.3 kWh/yr (~$12.05/yr) continuously. Closest competing matches include Revent RVL110 (110.0 CFM) and Revent RVLH110 (110.0 CFM).

How do flex elbows choke Delta SIG80-110HLED at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Delta SIG80-110HLED moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Delta SIG80-110HLED meet residential exhaust fan code specs?

Inspect Delta SIG80-110HLED mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series SIG80-110HLED / BreezSignature PD ID 2343185 (Qualified 2018-01-19)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (112.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Delta SIG80-110HLED airflow output?

Annual electricity figures and room square-footage ceilings below reflect Delta SIG80-110HLED tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Delta SIG80-110HLED
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 112 sq ft1 CFM/sq ft @ 112.9 CFM
Tall Bath (9-ft Ceiling)Up to 100 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 62 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.1 kWh/yr (~$0.50/yr)8.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.275.3 kWh/yr (~$12.05/yr)8.6 W x 8,760 hrs / 1,000

Which competing models share Delta SIG80-110HLED airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Revent RVL110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110 / 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL110 110 / 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127 / N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Utilitech UTLDR110 110 / 119 CFM 1.4 sones 9.4 CFM/W 4 in. diameter

How much airflow margin does Delta SIG80-110HLED give your bath?

Run a quick local room-volume check for Delta SIG80-110HLED by entering square footage and ceiling height to spot under-vented steam risks early.

Which bath layouts should avoid specifying Delta SIG80-110HLED?

Match Delta SIG80-110HLED directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 62 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 112 sq ft with 8-ft ceilings (100 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about Delta SIG80-110HLED?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Delta SIG80-110HLED.

What happens to Delta SIG80-110HLED CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Delta SIG80-110HLED moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does Delta SIG80-110HLED sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Delta SIG80-110HLED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Delta SIG80-110HLED cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Delta SIG80-110HLED 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Delta SIG80-110HLED pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110HLED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta SIG80-110HLED?

Delta SIG80-110HLED features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta SIG80-110HLED's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110HLED's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Delta SIG80-110HLED ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110HLED covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Delta SIG80-110HLED run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Delta SIG80-110HLED.