The Delta SIG80-110LED (BreezSignature) moves 110 CFM at 0.1 in. w.g. (108 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.3 CFM/W efficacy, sizing bathrooms up to 108 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta SIG80-110LED Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 110 / 108 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.3 CFM/W (#258/1,145)
- Static Retention
- 98.2% @ 0.25"
- Motor Draw
- 11.8 W (4.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Delta SIG80-110LED vs. 1,145-Model ENERGY STAR Benchmarks show?
Delta SIG80-110LED (EPA filing PD #2343189) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 108 CFM out of 110 CFM (98.2% retention, 10.5 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Delta maintains 121 active ENERGY STAR blowers; SIG80-110LED (series: BreezSignature) (PD #2343189) gained qualification on 2018-01-19. Lighting kit: Yes. At 9.3 CFM/W (#258 of 1,145, top 24.5% of 1,145 rated models, more efficient than 75.5% of rated models, 4.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.8 watts, about 4.3 kWh/yr (~$0.69/yr at $0.16/kWh) for 1 hr/day shower timers or 103.4 kWh/yr (~$16.54/yr) continuously. Closest competing matches include Utilitech UTLDR110 (110.0 CFM) and Utilitech UTLDS110 (110.0 CFM).
How does duct geometry alter Delta SIG80-110LED static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Delta SIG80-110LED?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Delta SIG80-110LED alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | SIG80-110LED / BreezSignature | PD ID 2343189 (Qualified 2018-01-19) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (108 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Delta SIG80-110LED ventilate safely?
Sizing outputs below convert Delta SIG80-110LED tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 108 sq ft | 1 CFM/sq ft @ 108 CFM |
| Tall Bath (9-ft Ceiling) | Up to 96 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 58 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.3 kWh/yr (~$0.69/yr) | 11.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 103.4 kWh/yr (~$16.54/yr) | 11.8 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Delta SIG80-110LED closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Utilitech UTLDR110 | 110 / 119 CFM | 1.4 sones | 9.4 CFM/W | 4 in. diameter |
| Utilitech UTLDS110 | 110 / 113.4 CFM | 1.4 sones | 8.9 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will Delta SIG80-110LED clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Delta SIG80-110LED satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Who should not install Delta SIG80-110LED in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Delta SIG80-110LED for residential use.
Limitations & Who Should Skip
- Steam or walk-in tub room > 58 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Ideal fit: Bathroom floor <= 108 sq ft with 8-ft ceilings (96 sq ft at 9-ft height)
- Primary match: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Delta SIG80-110LED?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Delta SIG80-110LED.
What electrical efficiency and runtime kWh define Delta SIG80-110LED?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Delta SIG80-110LED pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta SIG80-110LED's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta SIG80-110LED?
Delta SIG80-110LED features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta SIG80-110LED's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta SIG80-110LED's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Delta SIG80-110LED satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Delta SIG80-110LED clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Delta SIG80-110LED undersized or poorly matched for a bath renovation?
Skip Delta SIG80-110LED if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Delta SIG80-110LED CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Delta SIG80-110LED registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does Delta SIG80-110LED sound output compare to noisy contractor-grade fans?
Rated at an unpublished 0.1-in sone rating, Delta SIG80-110LED produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)